5 Calibration
5.4 Fine calibration
Continued
3
4
Continues on next page
88
Action
On the FlexPendant, tap on the
ABB logo to access the ABB menu
and tap on Calibration.
All mechanical units connected to
the system are shown along with
their calibration status.
Tap to select the mechanical unit
and then tap to select Calib.Para-
meters.Tap Fine Calibration..., a
dialog box is displayed prompting
to performing the actual calibra-
tion. A warning that updating the
revolution counters can change.
Programmed FlexPLP IRPLP 220
positions are also displayed. Tap
Yes to proceed.
© Copyright 2016 - 2018 ABB. All rights reserved.
Info/Illustration
xx1800002150
xx1800002151
xx1800002152
Product manual - FlexPLP IRPLP 220
3HAW050041018-001 Revision: C