Installation Procedure; Step 1 Checking And Preparing Accessories; Step 2 Choosing The Installation Location - Samsung AJTNLDCH Series Installation Manual

Table of Contents

Advertisement

Installation Procedure

Step 1 Checking and preparing
accessories
The following accessories are supplied with the indoor
unit. The type and quantity may differ, depending on the
specifications.
User's
manual(1)
Flexible hose (1)
Thermal insulation sponge
A (1)
Thermal insulation sponge
B (1)
Clamp hose(1)
Cable-tie(8)
Installation
manual(1)
Insulation drain (1)
Reducer(1)
Thermal insulation sponge
C (1)
Rubber(8)
Step 2 Choosing the installation
location
Installation location requirements
• There must be no obstacles near the air inlet and
outlet.
• Install the indoor unit on a ceiling that can support
its weight.
• Maintain sufficient clearance around the indoor
unit.
• Before installing the indoor unit, be sure to check
whether the chosen location is well-drained.
• The indoor unit must be installed such that it is
beyond public access and is not touchable by
users.
Do not install the air conditioner in following places.
• A location where there is mineral oil or arsenic acid.
Resin, flame, or accessories may drop or water may leak.
The heat exchanger capacity may decrease or the air
conditioner may be out of order.
• A place where corrosive gas such as sulphuric acid gas
generates from vent pipes or air outlets.
• The copper pipe or connection pipe may corrode and
refrigerant may leak.
• A place where machines may generate electromagnetic
waves. The air conditioner's control system may not
operate normally.
• The place where there is a danger of existing
combustible gas, carbon fibre or flammable dust.
• The place where thinner or gasoline is handled. Gas may
leak and it may cause fire.