• Connect the yellow/green wire (of the Floating switch cable) to the ground of the pump.
4. Operating mode
• When the water level in the tank or the vessel reaches the upper limit (i.e. when the float
reaches the upper limit), the pump starts automatically and empties the tank or vessel.
• When the water level in the tank or the tank is low (i.e. when the float reaches the lower
limit), the pump stops.
• To adjust the upper and lower height, simply adjust and fix the ballast weights to the
required height.

Operation

1. Connect the product cable to the pump.
2. Adjust the ballast weight to the desired trigger level.
3. Connect the pump to an electrical power source.
4. The pump will start and stop as soon as the floating switch reaches the set height.
Maintenance and storage
Before storing the product or performing any maintenance work, ensure that the
product is disconnected from its power source.
1. Maintenance
• Clean any plastic parts of the product with a soft, clean cloth.
• Do not use aggressive cleansers (solvents or abrasive cleansers) or an abrasive sponge
on the product.
2. Storage
• Always clean the product before storage.
• Store the product in a dry location that is protected from excessive heat and cold.
• Lock up the product and keep it out of the reach of children.
3. Frost-free conditions
• In operating temperatures of approximately 0 °C or colder, remove the floating switch from
the water and store it in a dry room to protect the product from frost.
4. Disposal
• Do not dispose of the product with regular household waste or dump it outdoors.
• Dispose of the product in a collection centre or waste drop-off facility for electrical and
electronic equipment waste. If in doubt, seek advice from your local municipality.
• Disposal of the product, accessories, and packaging should be carried out according to the
local regulations regarding environmental protection.
Care and cleaning
• Disconnect the product from the mains before cleaning.
• Do not use any aggressive cleaning agents, rubbing alcohol, or other chemical solutions, as
these may damage the housing and impair the functioning of the product.
• Clean the product with a dry, fibre-free cloth.
Declaration of Conformity (DOC)
Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschau hereby declares that this
product conforms to the 2014/53/EU directive.
Click on the following link to read the full text of the EU declaration of conformity:
www.conrad.com/downloads
Enter the product item number in the search box. You can then download the EU
declaration of conformity in the available languages.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the house-
hold waste. At the end of its service life, dispose of the product in accordance with
applicable regulatory guidelines.
You thus fulfill your statutory obligations and contribute to the protection of the environment.
Technical data
Description .................................... Floater switch
Model type .................................... FK-JH-X
Material class ................................ Pump Accessories – 06220
Voltage.......................................... 230 V
Current .......................................... 10 (5) A
Frequency ..................................... 50-60 Hz
Cable type .................................... H07RN-F 3G1.0mm2
Cable length ................................. 3 m (approx.) (BN 2302386)
10 m (approx.) (BN 2302387)
Protection ..................................... IPX8
Max. liquid temperature ................ 35 °C
Dimensions (L x W x H ................. 86 x 112 x 46 mm
Weight .......................................... 0.56 kg (BN 2302386)
1.47 kg (BN 2302387)
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights in-
cluding translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication
represent the technical status at the time of printing.
Copyright 2020 by Conrad Electronic SE.
*2302386_87_v1_1120_02_DS_m_4L_(1)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

23023872302386

Table of Contents