Sony DPP-FP95 Service Manual page 20

Digital photo printer
Hide thumbs Also See for DPP-FP95:
Table of Contents

Advertisement

4.
Push the sending decision button to CEC JIGU MODE with
the DIRECTION buttons (f,F). Set to turning on with the
DIRECTION buttons (f,F) and push the [ENTER] button.
Push the DIRECTION buttons (f,F) select to "Exit", and end
System Setting.
Under such a condition, this unit B is made to the HDMI CEC
SINK jig and comes to work.
*
CEC JIGU MODE cannot be turned off as long as this unit
power supply is not turned off when setting it to turning on
once. If the power supply of this machine is turned off once,
CEC JIGU MODE is automatically turned off.
Note: Please do not connect it with the SINK device like HDMI
monitor at CEC JIGU MODE ON.
HDMI CEC check
1.
Start this unit in the service mode. (Refer to Section 3-1-1. )
2.
"CEC/Freq Test" is selected with the DIRECTION buttons
(f,F), and the [ENTER] button is pushed.
DPP-FP95
3.
Connect this machine and the SINK jig (this unit "B") with the
HDMI cable and push the [ENTER] button of this unit.
Confirm becoming the display of "CEC Test: OK".
4.
Push the cancel button.
When CEC Test is OK, "OK" is displayed at the right of "CEC/
Freq Test" of the service mode start screen.
When CEC Test is NG
"NG" is displayed at the right of "CEC/Freq Test" of the service
mode start screen.
5.
End the service mode. (Refer to clause 3-1-1. )