Summary of Contents for ZIEHL-ABEGG ZETADYN 2

  • Page 1 Retrofit kit ZETADYN 2 - ZAdyn4C Technical Information Store for future use! R-TIA18_02-D-GB 2106 Part.-No. 00163466-D-GB...
  • Page 2: Table Of Contents

    Dimensions/minimum clearances ..........Ensuring the parameter values of the ZETADYN 2 .......
  • Page 3: Safety Instructions

    (R-TBA12_01). Observe the ZAdyn4C operating instructions. Information • If the ZETADYN 2 is operated with an EVAC 1C, the EVAC 1C must be replaced with an EVAC 3C. The EVAC 3C must be connected to the ZAdyn4C as described in the EVAC 3C operating instructions.
  • Page 4: Dimensions/Minimum Clearances

    4 Ensuring the parameter values of the ZETADYN 2 " Note the parameter values of the ZETADYN 2 in the parameter list alongside the parameter names. Set the parameter values on the ZAdyn4C after carrying out the mechanical and electrical installa- "...
  • Page 5 Technical Information Ensuring the parameter values of the ZETADYN 2 ZETADYN 2 ZAdyn4C Menu Installation & Motor Value Encoder & BC menu M&E (Encoder Type) ENC_TYP ZETADYN 2 ZAdyn4C Menu INTERFACES Value Encoder & BC menu GEBER ENC_INC enter the existing brake chopper or...
  • Page 6: Mechanical Installation

    In frequency inverters of the ZETADYN type, the intermediate circuit (terminals +DC / -DC) is still live even after switching off. You must wait at least three minutes. Replacement of the ZETADYN 2 with the ZAdyn4C Remove all lines connected to the ZETADYN 2. "...
  • Page 7: Assembly On The Zadyn4C 011-032

    Technical Information Mechanical installation Assembly on the ZAdyn4C 011-032 " Push the mounting plate (2) into the top groove (1) of the ZAdyn4C. Screw the M5 x 10 to M5 x 15 screws with washers two turns into the mounting plate. "...
  • Page 8: Assembly On The Zadyn4C 040-074

    Technical Information Mechanical installation Tighten M4 screw (8) . " Mount the retrofit kit cover. " Assembly on the ZAdyn4C 040-074 Insert the hook (1) of the fastening plate in the openings (2) on the right side of the ZAdyn4C. "...
  • Page 9 Technical Information Mechanical installation Screw on the fastening plate with the screw M4 (6). " Hook the with the openings at the side (8) into the top hooks on the fastening plate (7). Press the " down carefully until it is touching. Remove the retrofit kit cover.
  • Page 10: Electrical Installation

    Technical Information Electrical installation " Mount the retrofit kit cover. 6 Electrical installation General Danger! It is forbidden to carry out work on the frequency inverter when it is live. Even after disconnection, the DC-link ( terminals X2: +DC / X2:-DC ) is still live. Wait at least 3 minutes before working on the device Danger! Operating the ZAdyn4C with the housing covers removed is not permitted, as there are exposed...
  • Page 11: Connection Of Connecting Leads Running From The Retrofit Kit On The Zadyn4C

    Technical Information Electrical installation Connection of connecting leads running from the retrofit kit on the ZAdyn4C 6.2.1 Connection • The connecting leads running from the retrofit kit are connected to the ZAdyn4C. • The connecting leads are labelled. Lead Connection terminal on ZAdyn4C X-IN X-IN...
  • Page 12: Connection Of Connecting Leads On The Retrofit Kit

    Technical Information Electrical installation Connection of connecting leads on the retrofit kit 6.3.1 Connection Lead Connection terminal on retrofit kit Encoder output Brake monitoring Connecting leads on retrofit kit 1 X-I 2 Brake monitoring 3 X-K, Pins 1-4 4 X-K, Pins 5-13 5 Encoder output R-TIA18_02-D-GB 2106 Part.-No.
  • Page 13: Replacement Of The Connector On The X-K Connecting Lead

    Technical Information Electrical installation 6.3.2 Replacement of the connector on the X-K connecting lead Before connection to the retrofit kit, the connector on the X-K connecting cable must be replaced. Open the socket for the X-K connector by pressing the two tabs (1) on the sides of the socket "...
  • Page 14: Strain Relief

    Technical Information Electrical installation 6.3.3 Strain relief Cable ties must be attached to all connecting leads for strain relief. Attach the cable ties at the recesses provided on the retrofit kit housing (see figure). The shielding of the X-I connecting lead must be connected to earth potential on the retrofit kit. An earthing clip is provided for this purpose (see figure).
  • Page 15: Connection Of Connecting Leads On The Zadyn4C

    6.4.1.1 Replacement of ZETADYN 2 which has a circuit board produced after March 2001 with the ZAdyn4C This section describes what you have to do if a board from the time after March 2001 is installed in the ZETADYN 2.
  • Page 16 Technical Information Electrical installation Reconnect the leads from the ZETADYN 2 to the ZAdyn4C as described in the following table. " ZETADYN 2 ZAdyn4C Mains connection (X1) Mains connection (X1) -> -> -> Motor connection (X3) Motor connection (X3) ->...
  • Page 17: Replacement Of Zetadyn 2Cf Which Has A Circuit Board Produced Before March 2001 With The Zadyn4C

    Technical Information Electrical installation ZETADYN 2 ZAdyn4C Encoder connection asynchronous Encoder connection asynchronous motors motors (X-ENC8) Track A -> Track B -> N.C. -> N.C. Vcc (+ 5 V) -> +5/8V_E -> -> -> N.C. -> N.C. -> N.C. Shielding ->...
  • Page 18 Technical Information Electrical installation Reconnect the leads from the ZETADYN 2 to the ZAdyn4C as described in the following table. " ZETADYN 2 ZAdyn4C Mains connection (X1) Mains connection (X1) -> -> -> Motor connection (X3) Motor connection (X3) ->...
  • Page 19: Replacement Of The Connector On The X-O Connecting Lead

    Wires 7, 10 and 13 from the X-O connecting lead must be connected to normally closed contacts on the ZETADYN 2. They cannot be connected to the ZAdyn4C as there are no normally closed contacts on the ZAdyn4C. They are connected to the 3-pin connector.
  • Page 20: Start-Up

    Technical Information Start-up X-O connecting lead on ZAdyn4C X-O connecting lead on ZETADYN 2 7 Start-up General For details of commissioning the ZAdyn4C, refer to the “Commissioning” chapter in the ZAdyn4C operating instructions. If the absolute value encoder cable length is greater than 5 m, the operating voltage of the absolute value encoder has to be checked.
  • Page 21: Enclosure

    DIN EN 61800-5-1) Physical data Weight [kg] Dimensions h x w x d [mm] 242 x 161 x 63 Part no. Nachrüstsatz ZETADYN 2 - ZAdyn4C 110V 357315 Nachrüstsatz ZETADYN 2 - ZAdyn4C 230V 357314 R-TIA18_02-D-GB 2106 Part.-No. 00163466-D-GB 21/24...
  • Page 22: Connection Diagrams

    Technical Information Enclosure Connection diagrams Retrofit kit circuit suggestion on ZAdyn4C EU declaration of conformity - Translation - (english) A-KON18_01-GB 1941 Index 002 Manufacturer: ZIEHL-ABEGG SE Heinz-Ziehl-Straße 74653 Künzelsau Germany R-TIA18_02-D-GB 2106 Part.-No. 00163466-D-GB 22/24...
  • Page 23 The manufacturer is solely responsible for issuing this EU Declaration of Conformity. Product description: Retrofit kit Type: ZETADYN 2 - ZAdyn4C 110V adapter ZETADYN 2 - ZAdyn4C 230V adapter ZETADYN 3 - ZAdyn4C 110V adapter ZETADYN 3 - ZAdyn4C 230V adapter The above mentioned products of this declaration fulfil all relevant provisions of the following...
  • Page 24 Customer Service phone +49 7940 16-308 +49 7940 16-249 drives-service@ziehl-abegg.com Headquarters Ziehl-Abegg AG Heinz-Ziehl-Straße · 74653 Künzelsau Germany phone Tel. +49 (0) 7940 16-0 · fax Fax +49 (0) 7940 16-249 drives@ziehl-abegg.de www.ziehl-abegg.com...

This manual is also suitable for:

Zadyn4c