Troubleshooting - Little Giant Pit+Plus JR Owner's Manual

Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting

Problem
Circuit breaker tripped or
power turned off
Pump will not operate
Switch failure
Blocked discharge pipe
Blocked vent pipe
Check valve installed back-
wards
Pump runs, but does
Check valve stuck or
not discharge liquid
unplugged
Lift too high for pump
Inlet to impeller plugged
Pump is air-locked
Diaphragm switch
Weak or hardened rubber dia-
phragm
Plugged vent tube
Dirt or sediment lodged
between retainer ring and rub-
ber diaphragm causing con-
Pump does not shut off
tact to remain closed
when operating in
automatic control
(with External Control
Pump is air locked
Module)
Liquid inflow matches pump
capacity
Defective switch
Loose connection in level con-
trol wiring
Lift too high for pump
Low voltage, speed too slow
Pump does not deliver
rated capacity.
Impeller or discharge pipe is
clogged
Impeller wear due to abrasives Replace worn impeller.
No check valve in long dis-
charge pipe allowing liquid to
Pump cycles continu-
drain back into sump
ally
Check valve leaking
Basin too small for inflow
Probable Causes
Corrective Action
Reset circuit breaker or correct electrical supply
Disconnect electrical power. Remove the piggyback plug from the outlet.
Plug the pump power cable into the outlet. Turn on electrical power. If the
pump operates, the switch is in failure mode.
Clean discharge pipe.
Clean vent pipe. Make sure the air admittance valves are not restricting the
free passage of air in the vent pipe.
Check flow indicating arrow on check valve body to ensure it is installed
properly.
Remove check valve and inspect for proper operation.
Check rating table.
Pull pump and clean.
Consult the pump installation instructions. Make sure the 3/16" hole in the
discharge pipe inside the basin is not present or is blocked to allow air to
escape the pump volute.
Replace switch.
Replace rubber diaphragm.
Clear vent tube of any obstructions.
Clean area around rubber diaphragm.
Shut power off for approximately 1 minute, then restart. Repeat several
times to clear air from pump. If system includes a check valve, a 3/16" hole
should be drilled in discharge pipe approximately 2" above discharge con-
nections.
Larger pump required.
Disconnect switch, check with ohmmeter, open-infinitive resistance, closed-
zero.
Check control wiring.
Check rated pump performance.
Check for proper supply voltage to make certain it corresponds to nameplate
voltage.
Pull pump and clean. Check pipe for scale or corrosion.
Install a check valve in discharge line.
Inspect check valve for correct operation.
Install larger basin.
MAINTENANCE
Troubleshooting
7