DEWESOFT SIRIUSi-XHS Technical Reference Manual

DEWESOFT SIRIUSi-XHS Technical Reference Manual

Hybrid adc high bandwidth 5mhz 15ms/s alias-free high dynamic up to 1ms/s
Table of Contents

Advertisement

Quick Links

 
 
SIRIUSi-XHS®
TECHNICAL REFERENCE MANUAL 
 
SIRIUSi-XHS®
 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SIRIUSi-XHS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DEWESOFT SIRIUSi-XHS

  • Page 1     SIRIUSi-XHS® TECHNICAL REFERENCE MANUAL    SIRIUSi-XHS®  ...
  • Page 2: Table Of Contents

      Table of contents    1. About this document 4  1.1. Legend 4  1.2. Online versions 5  1.2.1. Online SIRIUSi-XHS® technical reference manual 5  1.2.2. DewesoftX® User Manual 5  2. Getting started 6  2.1. Software installation 6  2.2. Connecting SIRIUSi-XHS®...
  • Page 3 5. Safety instructions 42  5.1. General Safety Instructions 42  5.1.1. Environmental Considerations 42  5.1.2. Product End-of-Life Handling 42  5.1.3. General safety and hazard warnings for all Dewesoft systems 42  6. Notice 45  6.1. Warranty Information 45  6.2. Calibration 45  6.3. Support 45 ...
  • Page 4: About This Document

    1. About this document    This is the Technical Reference Manual for SIRIUSi-XHS® device, version ​ V 20-1.    SIRIUSi-XHS® is a high performance, high speed line of SIRIUS® real time data acquisition hardware            ...
  • Page 5: Online Versions

    TECHNICAL REFERENCE MANUAL    1.2. Online versions  1.2.1. Online SIRIUSi-XHS® technical reference manual  The most recent version of this manual can be downloaded from our homepage:  https://download.dewesoft.com/list/manuals-brochures/hardware-manuals  In the ​ H ardware Manuals section click the download link for the ​ S IRIUSi-XHS® technical reference  ...
  • Page 6: Getting Started

      2. Getting started    This chapter will help you to install the software, connect your SIRIUSi-XHS® device to the PC via  Ethernet or via USB, and will show you how to configure DewesoftX® software.     To follow these steps, you need the following items:  ...
  • Page 7: Connecting Siriusi-Xhs

    TECHNICAL REFERENCE MANUAL    2.2. Connecting SIRIUSi-XHS®  In this chapter, you can see the basic instructions for connecting SIRIUSi-XHS® devices over 3.0 USB  and RJ-45 ethernet connection. Advanced connections are described in the following chapters.  2.2.1. Connection over 3.0. USB  ...
  • Page 8: Sample Rate Limitation When Connected With Ethernet

    2.2.2.2. Ethernet configuration on the PC  As SIRIUSi-XHS® is a network device with static IP, you need to adjust the Network Card settings when  connecting it via Ethernet. The ethernet port on your SBOX, data logger or PC should be configured in a ...
  • Page 9: Troubleshooting

    IP replace IP with IP that is set on your device.  The result should be something like this:        I mage5: ping IP in Command Prompt            SIRIUSi-XHS® - V20-1 9/47   ...
  • Page 10: Dewesoftx® Settings For Siriusi-Xhs

    Settings item in the pop-up to open the DewesoftX® settings dialogue.        I mage6: DewesoftX® settings  In case the XHS device is connected via USB, the device will automatically be listed under the Dewesoft        ...
  • Page 11 Real-time controller option. If two Sirius-XHS devices are used, two different RT devices need to be                                 added to the device list.       SIRIUSi-XHS® - V20-1 11/47   ...
  • Page 12 Support of RT-devices is still an Experimental feature and it needs                               to be enabled under advanced -> Experimental settings.            SIRIUSi-XHS® - V20-1 12/47   ...
  • Page 13         I mage9: Adding the Real-time controller under Experimental      After that you will see a new Sirius-XHS or Dewesoft RT connection in the device tree.      I mage10: RT device Connection       ...
  • Page 14 DEVICE  TECHNICAL REFERENCE MANUAL      If the text by the device is disconnected, you should click on the device (Dewesoft RT Connection) , set                              ...
  • Page 15                         selecting time source. When you have only one device you can select the Dewesoft DAQ devices and                      ...
  • Page 16: Channel Setup Siriusi-Xhs

    DEVICE  TECHNICAL REFERENCE MANUAL    2.2.4. Channel Setup SIRIUSi-XHS®  When Dewesoft has started up, you will be in the Measure mode and see the Setup files list or you can                    ...
  • Page 17: Simple Measurement

                the measurement setup.  2.3.1. Help - Manual  Note that this document is just a quick start guide. For detailed information about Dewesoft consult the                    ...
  • Page 18: Sample Rate

                              SIRIUS will transfer to the Dewesoft. Higher sample rate also means that more data needs to be                      ...
  • Page 19: Measurement Mode

                    button.    Now Dewesoft has created a data file with all the data that you have seen during the recording session.                      ...
  • Page 20: Advanced Configuration

      2.4. Advanced configuration  Note, that the Dewesoft launcher has already done the hardware setup for you – you can check this in  ...
  • Page 21: Firmware Upgrade

    D ewesoft upgrade package​ (.dxu file) from the Dewesoft downloads page under  ● the section Drivers.   Copy the file into the Firmwares folder of your Dewesoft installation (e.g.  ● D:\DewesoftX\System\X3\Firmwares).   Connect the Dewesoft instrument to the PC and run Dewesoft X3.  ...
  • Page 22: Licensing

    DEVICE  TECHNICAL REFERENCE MANUAL    2.6. Licensing  SIRIUS-XHS or any other Dewesoft device already comes with an embedded Dewesoft license. You can                               ❶ ​  ...
  • Page 23: Troubleshooting

    TECHNICAL REFERENCE MANUAL    2.7. Troubleshooting  If your SIRIUSi-XHS® device is not found by DewesoftX® :   If you did not restart Windows after the software installation, restart now  ● Make sure that you have started DewesoftX® version Release Candidate 2020.2, Development  ...
  • Page 24: System Overview

                Sound pressure  USB 3.0  Ethernet  XCP/CCP  OPC UA   IP50                  -10°C to 50°C  Shock rating 50g              SIRIUSi-XHS® - V20-1 24/47   ...
  • Page 25: Main Features

                          ● functionality, award-winning DEWESoft X3 software is included. All upgrades to the software are                           free forever with no hidden licensing costs. ...
  • Page 26: Hybrid Adc Technology

    SIRIUS XHS, due to the nature of the chosen  filter, both modes are perfectly aligned and  synchronized.    As on any Dewesoft devices, data can be  synchronized to other data sources, such as  vehicle bus interface, GPS, IMU, video, and  others. ...
  • Page 27: Perfect Amplifiers For Power Measurements

    3.1.5. Power analyzer  Dewesoft software will automatically calculate and store not only raw data from the voltage and current  transducers but also all the power parameters: P, Q, S, D, Cos φ, power factor, P, Q, cos φ for each ...
  • Page 28: Data Acquisition Software Included For Free

    Max. Output Current  ±24 mA (±50 mA for 1 sec)  Max. Sync-cable length  100 m (Master/Slave), 200 m (IRIG)    3.3. Single slice  A single SIRIUSi-XHS® slice can have up to 8 measurement modules, currently HV, LV and ACC modules  are supported.      ...
  • Page 29: Single Slice: Rear Side

    TECHNICAL REFERENCE MANUAL        I mage44: ​ S IRIUS-XHS 8xACC      3.4. Single slice: Rear side  The SIRIUSi-XHS® chassis has following connectors at the rear side:        I mage45: ​ S IRIUSi-XHS® Rear side       Name ...
  • Page 30: Connectors

    Power out connector: pin-out (2-pin LEMO female)  Power Out connector (on the device): EXG.1B.302.CLL   Mating connector (for the cable): FGG.1B.302.CLAD52Z  The Power Out power plug can be used to daisy-chain several devices together.   Daisy chain cable: L1B2m-L1B2f          SIRIUSi-XHS® - V20-1 30/47   ...
  • Page 31: Sync Connector

                                SIRIUS slices usually have a CAN connector on the back side, while Rack version on the front side.        SIRIUSi-XHS® - V20-1 31/47   ...
  • Page 32: Gnd Connector

    HV modules.    3.5.5. Ethernet Connector  Connector used on the device is a standard ethernet connector (RJ45).  Standard ethernet cable with standard connector can be used to connect SIRIUS-XHS with a PC.        SIRIUSi-XHS® - V20-1 32/47   ...
  • Page 33: Usb Connector

      The Illustrations to the right show a USB-C and Standard size USB sockets.        I mage52 :USB-C connector on the device and USB connector on the PC, SBOX          SIRIUSi-XHS® - V20-1 33/47   ...
  • Page 34: Module Overview

    DEVICE  TECHNICAL REFERENCE MANUAL          4. Module overview  Currently HV, LV and ACC amplifierts are supported on the SIRIUSi-XHS® device.       XHS-HV  XHS-LV  XHS-ACC Connectors  BANANA  DB9  BNC  Counter version  -  -  -  Channels per slice ...
  • Page 35: Siriusi-Xhs® Dimensions

    DEVICE  TECHNICAL REFERENCE MANUAL    4.1. SIRIUSi-XHS® dimensions      I mage53: Dimensions              SIRIUSi-XHS® - V20-1 35/47   ...
  • Page 36: Hv: Specifications

    Gain Linearity  <0.02 %  Input Coupling  DC  Input Impedance  10 MΩ || 2 pF  Protection class  CAT III 600 V; CAT II 1000 V  Additional Specifications  Input connector  Banana              SIRIUSi-XHS® - V20-1 36/47   ...
  • Page 37: Hv- Banana Connector

    HV connector: pin-out (Banana plug)    Warning   It is mandatory to connect a ground cable to the GND connector of the SIRIUS® when you are  working with high voltages.    4.2.2. HV: Voltage          SIRIUSi-XHS® - V20-1 37/47   ...
  • Page 38: Specifications

    DSUB 9, BNC (others on request)  TEDS support  Standard + DSI® adapters  1) In- must be within ±10V referred to GND(iso); for Ranges ≥ 10 V the DC value of In- is not rejected          SIRIUSi-XHS® - V20-1 38/47   ...
  • Page 39: Dsub Connector

    DEVICE  TECHNICAL REFERENCE MANUAL    4.3.1. LV: DSUB connector      SIRIUSi-XHS®-8xLV    LV connector: pin-out (DSUB-9 female)    4.3.1.1. LV: Voltage       4.3.1.2. LV: Current          SIRIUSi-XHS® - V20-1 39/47   ...
  • Page 40: Bnc Connector

    DC or AC (1 Hz, 0.1 Hz)  Input Impedance  1 MΩ  Overvoltage Protection  50 V continuous; 200 V peak (10 msec)  I​ E PE mode  Excitation  4 or 8 mA  Compliance voltage  25 V  Output Impedance  >100 kΩ      SIRIUSi-XHS® - V20-1 40/47   ...
  • Page 41: Acc: Bnc Connector

    Input connector  BNC  TEDS support  IEPE mode only    4.4.1. ACC: BNC connector    SIRIUSi-XHS®-8xACC    ACC connector: pin-out (BNC)  4.4.1.1. ACC: Voltage, IEPE  Voltage  IEPE                      SIRIUSi-XHS® - V20-1 41/47   ...
  • Page 42: Safety Instructions

              Dewesoft d.o.o. assumes no liability for the customer’s failure to comply with these requirements.     All accessories shown in this document are available as an option and will not be shipped as standard    ...
  • Page 43                           Dewesoft sales and service office for service and repair to ensure that safety features are                        ...
  • Page 44                               and warnings in this manual.              SIRIUSi-XHS® - V20-1 44/47   ...
  • Page 45: Notice

    Dewesoft system can be requested. We retain them for at least one year, after system delivery.    6.3. Support  Dewesoft has a team of people ready to assist you if you have any questions or any technical difficulties      ...
  • Page 46: Printing History

                        Dewesoft triangle logo is a registered trademark but the ® sign is not used in the visual representation                        ...
  • Page 47: Documentation Version

    DEVICE  TECHNICAL REFERENCE MANUAL    6.9. Documentation version  Doc-Version  Date  Notes  [dd.mm.yyyy]  V20-1  13.05.2020  Initial version        SIRIUSi-XHS® - V20-1 47/47   ...

This manual is also suitable for:

Siriusi-xhs-pwr

Table of Contents