Download Print this page

Frico Thermozone AC 400 Quick Start Manual page 11

Advertisement

Complete technical documentation is
available.
EC Declaration of Conformity
Defined by the EC Electromagnetic
Compatibility Directive 89/336/EC och
92/31/EC.
The following harmonised standards are in
use:
SS-EN 50 082-1: 1992
SS-EN 60 555-2/3: 1991
Complete technical documentation is
available.
Type
Power
Voltage, motor / manouvre
Voltage, heat output
Voltage, motor / manouvre
Amperage heat output
Air flow
Temperature rise of passing
air at full output
Sound level
Weight
Length
Protection class
Accessories
Air flow selector (4-step)*
Air flow selector high/low *
Air flow regulator (stepless), AC 401-402 *
Output selector
(0 –
Position limit switch
2-step thermostat
Mounting plate for vertical mounting
Adaption set for ceiling mounted sliding doors
Adaption set for ceiling mounted sliding doors
False ceiling grille (1192 x 192)
False ceiling grille (1515 x 192)
*
Regulation for a max of 3 units
1
*
2
Regulation for a max of 1 units (2xAC401)
Thermozone AC 400
[kW]
[V]
[V]
[A]
[A]
[m
/h]
3
[°C]
[dB(A)]
[kg]
[mm]
1
1
2
/
/
1
1
2
1)
Partille, 19 januari 1998
Mats Careborg
Technical Manager
AC401
AC402
0,6
1,0
230~
230~
-
-
2,6
4,3
-
-
1350 / 2700 2250 / 4500
-
-
44 / 62
45 / 63
44
71
1000
1670
IP 24
IP 24
Type
ACR 304
ACR 3042
2221AG
EV 300
AGB 304
KRT 2800
AVMP 300
AXT401
AXT402
22003
22004
AC412
AC418
12
18
230~
230~
400V3~
400V3~
2,5
4,3
17,3
26,0
1350 / 2700 2250 / 4500
27 / 13
27 / 13
44 / 62
45 / 63
54
86
1000
1670
IP 24
IP 24
Measures (BxLxD)
80x100x90 mm
150x200x105 mm
85x170x63 mm
80x100x90 mm
60x165x60 mm
GB