DIMENSIONS AND WEIGHTS

ASinterface connector with 3-pin DIN 46244 plug (size 22)
Without input
Weight: 38 g
22
2
2 1
51
ASinterface connector with ISO 4400 / DIN 43650-A plug (size 30)
Without input
Weight: 42 g
30
2
3
1
2
5 female pins M12 base for input
1
Yellow cable (ASinterface)
2
Black cable (power supply)
3

ELECTRICAL CHARACTERISTICS

Connector with M12 input :
• M12 base, 5 female pins
• Designed for 1 or 2 inputs
• M12 connector contact 1 current (24 V): <200 mA
• Load current per entry: 2.4 mA
• Trigger level of one input : 0,36 mA
• Logic level for inputs:
- High : +10 . . . 30 V DC
- Low : -30 . . . 2.5 V DC
This product complies with the essential
requirements of the EMC-Directive 89/336/EEC
and amendments. Certified CE. A separate
Declaration of Conformity is available on request.
A separate Declaration of Incorporation relating to EEC-
Directive 89/392/EEC Annex II B is available on request.
Please provide acknowledgement number and serial
numbers of products concerned.
MS-P522
With M12 input (Version A)
Weight: 54 g
22
3
2 1
5
With M12 input (Version A)
Weight: 58 g
30
3
3
1
2
51
5
ASinterface CONNECTORS - SERIES 881
2
3
1
51
5
2
3
1
51
5
Connection to M12 connector
Contact
Name
1
24V DC IN
2
IN x
3
GROUND
4
IN x +1
5
PE
Input wiring diagram
Male connector thread side view
2-wire sensor
24V
24V
4
1
Sensor
Sensor
x+1
5
x
3
2
IN x+1
IN x
Compatible with inductive detectors if the leak current is less than 0.3 mA
with a switching threshold, at ground state, of less than 4V.
Input signal addressing
D0, D1, D2, D3: data bits for ASinterface slave (one non two-directional node)
Connector
D0
No input
Output (coil)
With inputs
Output (coil)
If the ASinterface network is configured with an ASinterface coupler
integrated in the PLC, the following ASCO/JOUCOMATIC ASinterface connector
identification codes apply
ASCO/JOUCOMATIC connector
identification code
ASinterface connectors are non rotatable
With M12 input (Version B)
Weight: 54 g
2 1
22
With M12 input (Version B)
Weight: 58 g
30
2
3
1
2
Description
Input power
Positive logic input x
Ground (3-wire sensors
Positive logic input x +1
Earth
3-wire sensor
(e.g. solid state)
24V
4
+
IN
Sensor
x+1
x+1
-
3
GND
D1
D2
Not used
Not used
Not used
Input 1
I/O
code
11 (or BH)
51
5
1
2
3
3
1
51
5
24V
1
+
IN
Sensor
5
x
x
-
2
GND
D3
Not used
Input 2
ID-code
15