To optimise the effective lifetime of your welding equipment and avoid the additional cost of replacement, regular
maintenance is important. Replace all damaged parts immediately to ensure correct levels of protection.
Before use
• Helmet and head harness. Inspect for cracks or any
damaged or defective parts. Replace if needed.
• Cover lenses. To provide the best possible
vision they should be clean and without scratches.
• Face seal. If the face seal is damaged there is a great
risk that contaminated air will get inside the helmet.
Verify it's in position and free from splits and tears.
• Welding lens. Ensure low battery is not flashing
and check that the sensors are clean and uncovered.
• Breathing tube. Confirm tube is not damaged or
leaking any air. To extend the life of breathing tube,
use a tube cover or a heavy-duty rubber tube.
52 80 25
42 20 00
52 60 00
50 00 26
52 70 00
53 10 00
52 70 70
Part No
Description
Part No
169005
HEAD PROTECTION 9100
171021
169010
THROAT PROTECTION 9100
171022
169100
HEAD CAPE TECAWELD
171023
169502
SWEATBAND 9100 & 9100 FX PK=2
171024
169505
SWEATBAND 9100 & 9100 FX PK=5
422000
169550
SWEATBAND 9100 & 9100 FX PK=50
500026
171020
LENS MAGNIFYING 1.0X 9100 100 & 9000
502800
Unit 13, 39 Herbert Street • St Leonards NSW 2065 • Australia
Welding Helmet 9100 Air
After use
• Clean the helmet. Wipe with a moist tissue or cloth,
both inside and outside the helmet. If you suspect that the inside
of the airduct is dirty, it must be changed.
DO NOT rinse, immerse in water or clean with solvents.
• Face seal and sweatband. Remove for additional cleaning as needed
and replace if they become unhygienic.
• Cover lenses. Clean with a soft cloth and replace if any pits or
scratches occur.
• Breathing tube. Replace if damaged, deformed or leaking any air.
• Storage. Store the helmet in a dry, clean area away from direct
sunlight, high temperatures and solvents.
16 91 00
16 90 10
17 10 20
17 10 21
17 10 22
17 10 23
17 10 24
Description
Part No
LENS MAGNIFYING 1.5X 9100 100 & 9000
526000
LENS MAGNIFYING 2.0X 9100 100 & 9000
527000
LENS MAGNIFYING 2.5X 9100 100 & 9000
527070
LENS MAGNIFYING 3.0X 9100 100 & 9000
528025
BATTERY LITHIUM 9100, 100 & 9000 PK=2
531000
LENS WELDING 9100XXi SPEEDGLAS
532100
HELMET WELDING 9100 AIR EXC LENS
533000
Authorised 3M Wholesaler
T: (02) 9439 0111 • F: (02) 9439 0100
E: sales@awsi.com.au
W: www.speedglas.com.au
16 95 02
16 95 05
16 95 50
53 61 00
53 30 00
Description
Part No
Description
LENS COVER OUTER STD 9100 PK=10
533505
ADAPTOR ADFLO BREATHING TUBE 9100 AIR
COVER LENS OUTER HC 9100 PK=10
533700
AIR DUCT BACK PART 9100 AIR
LENS COVER OUTER HT 9100 PK=10
534100
FACE SEAL 9100 AIR
LENS COVER INNER 9100XX PK=5
536000
HEAD HARNESS PIVOT MECHANISM 9100
HOLDER BATTERY 9100
536100
HEAD HARNESS FRONT PART 9100
COVER FRONT SILVER 9100XXi
536200
HEAD HARNESS BACK PART 9100
HEAD HARNESS 9100
790101
CARRY BAG SPEEDGLAS
Further information and advice
To request a quote or place an order for spare parts, please contact TWS on +61 (0) 7 4659 0044 or visit www.tweld.com.au. Please note that higher than normal levels
of pollutants, heat and sparks will require more frequent replacement of components. If you require additional guidance, please check the care and maintenance videos on our
YouTube Channel (www.youtube.com/user/3MSpeedglas) or contact your local TWS representative.
16 90 05
53 60 00
53 62 00
53 21 00
53 37 00
53 41 00
50 28 00
53 35 05
79 01 01

Advertisement

loading

Summary of Contents for 3M Speedglas 9100 Air Series

  • Page 1 HEAD HARNESS 9100 790101 CARRY BAG SPEEDGLAS Authorised 3M Wholesaler Further information and advice Unit 13, 39 Herbert Street • St Leonards NSW 2065 • Australia To request a quote or place an order for spare parts, please contact TWS on +61 (0) 7 4659 0044 or visit www.tweld.com.au. Please note that higher than normal levels T: (02) 9439 0111 •...
  • Page 2 • Inspect breathing tube - ensure it is free from splits or holes. Replace if necessary • Disinfect surfaces with 3M 504 Cleaning Wipes • Inspect belt - ensure it is free from splits or tears and • Store in a dry, clean area / locker away from direct sunlight, high...

This manual is also suitable for:

Versaflo v-500e