95-10294 V2016-10-20 IF-800 VP
IF-800 VP
1 IF-800-VP
Thank you for using a terminal of the series IF-800 VP for recording access
data
(VP= vandal-proof, degree of protection in accordance with DIN EN 50102
IK08).
Scope of delivery:
Housing ring with IF-800 VP slave terminal with 5 m connecting cable
Screw cover with Makrolon insert
I/O controller board for controlling locking devices
Terminal strip board
Material for fastening
Please check the completeness and condition of the shipment upon
receipt.
2 Usage in Accordance with the Intended Purpose
IF-800 VP terminals are devices for controlling the access of persons as well as for controlling and
monitoring locking devices. Any other use is not in accordance with the intended purpose and is therefore
not permitted.
The internal hardware of the IF-800 VP is identical to that of the IF-800 slave terminal. For more information
on connections and required settings, please refer to the IF-800 documentation no. 95-10287.
3 Function of the IF-800-VP Slave Terminal
In general, IF-800 VP slave terminals are connected to a master terminal, an access manager or a terminal
controller via an RS485 data cable. Terminals of the series IF-800 VP are designed for controlling the access
of persons, who identify themselves with RFID credentials, as well as for controlling and monitoring locking
devices.
We recommend:
installing a separate, fuse-protected circuit.
keeping a minimum distance of 30 cm between the slave terminal and other systems with RFID readers.
keeping a distance of 10 cm between connecting cables and power lines.
Interflex Datensysteme GmbH
1/7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IF-800 VP and is the answer not in the manual?

Questions and answers

Summary of Contents for Interflex IF-800 VP

  • Page 1 Any other use is not in accordance with the intended purpose and is therefore not permitted. The internal hardware of the IF-800 VP is identical to that of the IF-800 slave terminal. For more information on connections and required settings, please refer to the IF-800 documentation no. 95-10287.
  • Page 2: Opening/Closing The Housing

    To open, place the opening tool over the IF-800 VP. Make sure that the marking on the opening tool is exactly at the top. Then, place the vacuum lifting pad on the IF-800 VP. Now, the cover of the terminal can be screwed open.
  • Page 3: Shielded Cables

    3. Set the hardware address. 4. Install the IF-800 VP. At the installation site, fasten the IF-800 VP to a wall or pillar. 5. Switch on the operating voltage. 6. Perform initial operation and check the functions of the device.
  • Page 4: Electrical Connections

    Connection to control element (up to max. 30 V, 2 A) J-Y(ST) Y 4x2 x 0.6 mm² Spur line from BUS to installation site. 100 m J-Y(ST) Y 4x2 x 0.6 mm² RS485 BUS cable 1200 m J-Y(ST) Y x2 x 0.6 mm² Interflex Datensysteme GmbH...
  • Page 5 7 Connections Terminal strip board Circuit example: Control of a control element (door opener) I/O controller board Circuit example: Connection of the two inputs Circuit example: Power supply Circuit example: IF-800-VP terminal Circuit example: RS485 connection Interflex Datensysteme GmbH...
  • Page 6 DIP switches for LEDs. This switch is factory preset and may not be changed. Anti-tamper switch Screw for adjusting the reader DIP addressing switch Latch lever. Please read the note below. Check whether the latch lever can easily be moved. After installation, the latch lever must point downward. Interflex Datensysteme GmbH...
  • Page 7: 11 Technical Specifications

    The owner can dispose of the device himself or return it to the supplier. Copyright © 2016 Version Date: October 28, 2016 Interflex Datensysteme GmbH Zettachring 16, D-70567 Stuttgart, Germany Tel.: +49 (0711) 1322 0 Internet E-Mail: interflex.info@allegion.com Websites: www.interflex.de www.allegion.com...

Table of Contents