Fastech Ezi-SPEED ESD-30-C Manual page 50

Bldc motor speed control system
Table of Contents

Advertisement

Connector : CN4
Manufacturer : DEGSON
Part number : 15EDGKD-2.5-13P-14-12A (PCB connector - Plug)
Connector part number : 15EDGKD-13P
Pin allotment of CN4
Pin
Terminal
Input/Output
No.
Name
1
HCOM
Common
2
X0
Input
3
X1
Input
4
X2
Input
5
X3
Input
6
X4
Input
7
LCOM
Common
8
Y0+
Output
9
Y0-
10
Y1+
Output
11
Y1-
12
Y2+
Output
13
Y2-
* Function in [ ] is assigned at shipment
Can be assigned required functions to 5 input signals(X0~X4) and 3 output signals (Y0~Y2)
• Input signals : Can be used 5 functions out of FWd(CW rotation), rEv(CCW rotation),
P0(operation data 1), P1(operation data 2), P2(operation data 2), A.rst(Alarm reset), E.Err(External
alarm), H-Fr( Motor activation / deactivation)
• Output signals : Can be used 3 functions out of SPd(Speed output), AL.on( Alarm output),
AL.ov(Overvoltage alarm output), OvLd(Overload alarm output), Mov(Motor operation output),
vA(Speed attainment alarm), WnG(Warning alarm)
Internal
Ext. Pwr
Signal
Power
Source
Name
Supply
Logic
-
[FWd]
+
+
[rEv]
+
+
[P0]
+
+
[P1]
+
+
[A.rSt]
+
+
-
Free
Free
[SPd]
polarity
polarity
Free
Free
[AL.on]
polarity
polarity
Free
Free
[MovE]
polarity
polarity
-50-
13
Ext. Pwr
Sink
Logic
Input signal common : Sink Logic : +24V,
+
Source Logic : 0V (GND)
The motor rotates is FWD direction
-
during signal "ON
The motor rotates is REV direction during
-
signal "ON"
-
Select the operating data
-
Select the operating data
-
Reset the alarm
Input signal common
Free
For every rotation of the motor, 30 pulses
polarity
are output
Free
It turns off when an alarm is generated (N
polarity
ormally closed)
Free
It turns on when the motor is operated
polarity
(Normally opened)
1
Description

Hide quick links: