4. Specifications and dimensions of the motor
4.1 Specifications
Specifications
Item
Rated Output
Power(Continuous)
Rated Torque
Rated Output
Current
Rated Speed
Permissible Load
Inertia Moment
Inertia Moment
Weight
Length
Permissible
Overhung Load
Promissible Thrust
Load
General specifications
Item
Insulation Resistance
Dielectric Strength
Temperature Rise
ESM-60-H-
Unit
30
W
30
N-m
0.096
A
0.17
r/min
0.5
−4
2
10
Kg − m
0.086
−4
2
10
Kg − m
Kg
0.5
mm
62
10mm from
70
Shaft : [N]
20mm from
100
Shaft : [N]
Please don't thrust load. An unavoidable situation, please
N
100MΩ or more when DC500V Mega tester is applied between
coil and case after continuous operation under normal
temperature and humidity.
Sufficient to withstand when 1500VAC, 60Hz applied between
coil and case for 1 minute after continuous operation under
normal temperature and humidity.
The temperature rise od the coil is 60℃ max. and that of the
case surface is 50℃ max. measured by thomocouple after rated
continuous operation under normal temperature and humidity.
ESM-80-
H-60
60
0.191
0.43
1.8
0.234
0.8
74
120
140
keep thrust load less than 50% of motor weight.
Motor
-16-
ESM-90-
ESM-104-
H-120
H-200
120
200
0.382
0.637
0.89
1.60
3000
5.8
5.8
0.61
0.66
1.3
2.4
94
156
160
160
170
160
ESM-104-
H-400
400
1.27
2.31
8.75
0.66
2.4
156
170
170