Maruson PowerMax User Manual

Advertisement

Quick Links

PowerMax UPS
MAX-650A
Please read and understand this instructions manual. This manual provides safety,
installation and operation which will guide you to the best performance of your
equipment. Please keep this manual. It includes important instructions for the
safe usage of the equipment and to obtain manufacturer's support in case of need.
Please keep or recycle the packaging materials! Packaging materials used in our
products are designed to provide from transportation. These materials are
necessary in case that the damage that may occur during the shipment is not
covered by the product's warranty.
1. Introduction
1-1 System description
This Line Interactive UPS with LED indicators, newest technology and
powerful function.
This Line Interactive UPS is designed with 2-Steps Boost and 1 step Buck
AVR to stabilize input voltage. Input voltage range is -30% +25%, but
output regulation is +/-10%.
This Line Interactive UPS provides you with the ability of protection for your
critical devices.
1-2 Features
• Line Interactive design
• Microprocessor control guarantees high reliability
• Frequency 50/60 auto-sensing
• Equipped with 2-Steps Boost & 1-Step Buck AVR to stabilize utility
voltage
• Built-in DC start function enable UPS to be started up without AC power
supplied
• UPS Green Mode (Optional)(Energy Saving Function)
• Off-mode Charging
• Over/Low Voltage. Short-Circuit, and Lighting/Surge(Optional) Protection
• Built-in CCCV (Constant Current, Constant Voltage) battery Charger
2. Caution
Be sure to operate within the power rating of the UPS. Bellow 1/2 or 1/3 of the
rated power recommended for longer backup time & longer battery life.
Do not place the UPS near excessive humidity, under direct sunshine, or close
to heat-emitting sources.
If the UPS is out of order, detach the power cord and consult your dealer right
away. Do not remove cover; there is no serviceable part inside.
The unit should be supplied by a grounded source. Do not operate the unit
without a ground source.
The socket should be installed near the equipment and be easily accessible.
Do not plug the UPS's power cord into itself. That will result in a safety hazard.
A qualified technician or electrician in accordance with local electrical code
should perform installation.
The UPS contains voltage that is potentially hazardous. Qualified or certified
technician should proceed all repairs and maintenance.
The UPS has its own integral energy source (battery). The output receptacles
may be active even when the UPS is not connected to an AC supply.
The UPS is suitable for computers and electronic equipment with substantial
rectifier or capacitive loads, not suitable for electronics equipment with
significant inductive loads, such as motors & fluorescent lamps.
3. Installation
The UPS must be installed in a protected environment away from heat-emitting
appliances such as a radiator or heater. Do not install this product where
excessive moisture is present.
CAUTION: Never connected a laser printer or plotter periodically draws
significantly more power than its idle status, and may overload the UPS.
4. Overview
4-1 Front Panel
(1) Main Power Button: On/Off or Silence button and indicate UPS
statuses
USER'S MANUAL
4-2 Top Panel
(1) Battery back-up & AVR protection outlets
(2) Surge Protection Outlets
4-3 Rear Panel
(1) AC Input: Connect to input power cord
(2) AC Circuit Breaker
5
Operation
5-1 When UPS is connected to city utility, but UPS is not powered on, UPS will
charge battery automatically and Blue LED button will flash every 2
seconds.
Please press main switch on front panel for 1 second to turn UPS on.
5-2 To turn Off UPS when UPS is under AC mode, please press main switch on
front panel for 4 seconds.
To turn off UPS when UPS is under battery mode, please press main switch
and then UPS will shut down completely in 10 seconds.
This UPS is designed with "Off-mode charging", so UPS will charge battery
continuously when UPS is under AC normal. If users intend to power off
UPS completely, users have to plug out power cord from city utility.
5-3 DC Start:
Press on main switch for 4 seconds when city utility is black out, UPS will
be turned on and then go back up mode. To turn off UPS, please press
main switch for 4 seconds again. If users want to turn on UPS again, please
wait for 10 seconds to press main switch for 4 seconds again.
5-4 When UPS is under batter mode and battery voltage is too high or low,
buzzer will keep.
5-5 Buzzer will keep twice every 8 seconds when AC power is black out. To
silence alarm please simply press main switch. To re-start alarm, please
press main switch again.
6
Storage
To ensure battery lifetime, please kindly read and also follow below instruction
completely.
This unit is shipped from factory with its internal battery fully charged, however,
some charge maybe lost during shipping and the battery should be recharged
prior to use. Plug the unit into an appropriate power supply and allow the UPS
to charge fully by leaving it plugged at least 10 hours.
Extended Storage
Storage Temperature
5 to 86° F
(-15 to 30° C)
86 to 113° F
(30 to 45°C)
Recharge Frequency
Charging Duration
Every 6 Months
Every Month
10 Hours
10 Hours

Advertisement

loading

Summary of Contents for Maruson PowerMax

  • Page 1 USER’S MANUAL PowerMax UPS MAX-650A Please read and understand this instructions manual. This manual provides safety, installation and operation which will guide you to the best performance of your equipment. Please keep this manual. It includes important instructions for the safe usage of the equipment and to obtain manufacturer’s support in case of need.