• To reduce the risk of fire, combustion, or
accumulation of combustible gases, DO NOT
exhaust dryer air into an enclosed and
unventilated area, such as an attic, wall, ceiling,
crawl space, chimney, gas vent, or concealed
space of a building.
• To reduce the risk of fire, DO NOT exhaust the
dryer with plastic or thin foil ducting.
• Do not exceed the recommended duct length
limitations noted in the chart. Failure to follow
these instructions may result in extended drying
times, fire or death.
• Do not crush or collapse ductwork.
• Do not allow ductwork to rest on or contact
sharp objects.
• If connecting to existing ductwork, make sure it
is suitable and clean before installing the dryer.
• Venting must conform to local building codes.
Ductwork
Wall Cap Type
Recommended
a
a
a: 4 '' (10 cm)
Use for only short run installations
b
b: 2 1/2 '' (6.4 cm)
NOTE
• Deduct 6 ft. (1.8 m) for each additional elbow. Do not use more than four 90° elbows.
• In Canada, only those foil-type flexible ducts, if any, specifically identified for use with the appliance by
the manufacturer should be used. In the United States, only those foil-type flexible ducts, if any,
specifically identified for use with the appliance by the manufacturer and that comply with the Outline
for Clothes Dryer Transition Duct, Subject 2158A, should be used.
Routing and Connecting Ductwork
Follow the guidelines below to maximize drying
performance and reduce lint buildup and
condensation in the ductwork. Ductwork and
• Use only 4 '' (10 cm) rigid, semi-rigid or flexible
metal ductwork inside the dryer cabinet and for
venting outside.
• The exhaust duct must be 4 '' (10 cm) in diameter
with no obstructions. The exhaust duct should
be kept as short as possible. Make sure to clean
any old ducts before installing your new dryer.
• Rigid, semi-rigid or flexible metal ducting is
recommended for use between the dryer and
the wall. All non-rigid metal transition duct must
be UL-listed. Use of other materials for transition
duct could affect drying time.
• Ductwork is not provided with the dryer. You
should obtain the necessary ductwork locally.
The vent hood should have hinged dampers to
prevent backdraft when the dryer is not in use.
• The total length of flexible metal duct must not
exceed 8 ft. (2.4 m).
Number of 90°
Maximum length of 4-inch diameter rigid
Elbows
0
1
2
3
4
0
1
2
3
4
fittings are NOT included and must be purchased
separately.
• Use 4'' (10 cm) diameter rigid, semi-rigid or
flexible metal ductwork.
INSTALLATION
metal duct
65 ft. (19.8 m)
55 ft. (16.8 m)
47 ft. (14.3 m)
36 ft. (11.0 m)
28 ft. (8.5 m)
55 ft. (16.8 m)
47 ft. (14.3 m)
41 ft. (12.5 m)
30 ft. (9.1 m)
22 ft. (6.7 m)