1 − Transformer T5
Transformer T5 is used on all J" voltage units. T5 is used as a
step-down transformer for the outdoor fan motor. The
transformer is located inside the unit control box (see figure 3).
The transformer is rated at 3.4 VA with a 575 volt primary and
a 460 volt secondary.
HP29 THREE-PHASE UNIT CONTROL BOX
RUN CAPACITOR
(C1)
COMPRESSOR
CONTACTOR
(K1)
GROUNDING
LUG
FIGURE 3
HP29 SINGLE-PHASE UNIT CONTROL BOX WITH
RECIPROCATING COMPRESSOR
START
CAPACITOR
(C7)
COMPRESSOR
CONTACTOR
(K1)
GROUNDING
LUG
FIGURE 4
2 − Dual Capacitor C12
The compressor (scroll or reciprocating) and fan in
single-phase units use permanent split capacitor motors. The
capacitor is located inside the unit control box (see figure 4 and
5). A single dual" capacitor (C12) is used for both the fan
motor and the compressor (see unit wiring diagram). The fan
side and the compressor side of the capacitor have different
MFD ratings. See table 1 for dual capacitor ratings.
TRANSFORMER(T5)
J" VOLTAGE
UNITS ONLY
OUTDOOR FAN
RELAY (K10) G"
& J" VOLTAGE
UNITS ONLY
DEFROST
CONTRO
L
(CMC1)
DUAL CAPACITOR
(C12)
POTENTIAL
RELAY (K31)
DEFROST
CONTROL
(CMC1)
Page 4
HP29 SINGLE−PHASE UNIT CONTROL BOX
WITH SCROLL COMPRESSOR
COMPRESSOR
CONTACTOR
(K1)
GROUNDING
LUG
FIGURE 5
TABLE 1
HP29 (C12) DUAL CAPACITOR RATING
Unit
Terminal
FAN
HP29−211
HERM
FAN
HP29−261
HERM
FAN
HP29−311
HERM
FAN
HP29−411
HERM
FAN
HP29−461/511
HERM
FAN
HP29−651
HERM
FAN
HP29−018
HERM
FAN
HP29−024
HERM
FAN
HP29−030
HERM
FAN
HP29−036
HERM
FAN
HP29−042
HERM
FAN
HP29−048
HERM
FAN
HP29−060
HERM
DUAL CAPACITOR
(C12)
DEFROST
CONTROL
(CMC1)
MFD
VAC
5
25
5
30
5
370
35
5
40
7.5
50
7.5
440
70
5
25
5
370
30
5
35
5
40
440
7.5
40
7.5
60
370
7.5
80