RESI®
RESI
Date:
Informatik &
Version:
Automation
Edited by:
GmbH

RESI-MBUSxLVL-ETH

Great care has been taken in the creation of the text, illustrations and
program examples in this manual. The editors and publishers accept
no responsibility for any inadvertent omission of entries or for
typographical or other errors herein. Nor can they be held responsible
or liable for consequences arising from any errors herein.
This manual is subject to copyright law. All rights are reserved.
This manual may not be copied in part or whole in any form including
electronic media without the written consent of RESI. Neither may it be
transferred in any other language suitable for machines or data
processing facilities. Also rights for reproduction through lecture, radio
This documentation and the accompanying software are copyrighted
© Copyright 2005 – 2020 by RESI Informatik & Automation GmbH
Great care has been taken in the creation of the text, illustrations and
program examples in this manual. The editors and publishers accept
no responsibility for any inadvertent omission of entries or for
05.10.2020
Client:
typographical or other errors herein. Nor can they be held responsible
1.0
or liable for consequences arising from any errors herein.
DI HC Sigl,MSc
Title:
This manual is subject to copyright law. All rights are reserved.
This manual may not be copied in part or whole in any form including
electronic media without the written consent of RESI. Neither may it be
or television transmission are reserved.
by RESI.
RESI-MBUSxLVL-ETH Manual
Pages
41

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RESI-MBUS LVL-ETH Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Resi RESI-MBUS LVL-ETH Series

  • Page 1: Resi-Mbusxlvl-Eth

    This manual is subject to copyright law. All rights are reserved. This manual may not be copied in part or whole in any form including electronic media without the written consent of RESI. Neither may it be transferred in any other language suitable for machines or data processing facilities.
  • Page 2: History

    RESI® 1 History Date Editor Description 05.10.20 DI HC Sigl, MSc Initial version Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 3: Table Of Contents

    ............................8 SSEMBLING RESI-MBUS LVL-ETH ............10 SWITCH SETTINGS AND TERMINALS OF RESI-MBUS LVL-ETH ..................... 12 IRING DIAGRAM 6 RESI-MBUSXLVL-ETH OPERATION MODES ....................13 7 RESI-MBUSXLVL-ETH WEB CONFIGURATION .................... 14 HOWTO ......................... 15 SETUP ADDRESS HOWTO ....................... 16 CHANGE SOCKET NUMBER HOWTO ..................
  • Page 4: Important Security Notes

     Subsequent damages, which results from faults of this device, are excluded from warranty and liability!  Only the technical data, wiring diagrams and operation instructions, which are part to the product shipment are valid! Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 5  Dimensions of the enclosures or enclosures accessories may show slight tolerances on the specifications provided in these instructions!  Modifications of this documentation is not allowed!  In case of a complaint, only complete devices returned in original packing will be accepted! Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 6: General Information

    RESI® 4 General Information The RESI-MBUSxLVL-ETH gateways are designed for integrating MBUS smart meters via Ethernet interface into an own building automation or industrial solution with a host system, which is able to interpret the MBUS standard protocol. The converters offer the following features: ...
  • Page 7: Technical Data For Resi-Mbusxlvl-Eth

    RESI® Technical data for RESI-MBUSxLVL-ETH Technical Data RESI-MBUSxLVL-ETH Power supply Supply voltage 12-48 V= +/-10% Storage temperature -20...85 °C Power LED Operating 0...60°C Temperature Power consumption <8.4W Humidity 25...90 % rH non- condensing Protection Class IP20 (EN 60529) Serial interface Dimensions LxWxH 35.8mm x 90mm x 58mm...
  • Page 8: Mounting And Connections

    5 Mounting and Connections Assembling Our RESI-MBUSxLVL-ETH converters are designed for mounting on a 35mm DIN-EN50022 rail. Please note, we use symbol pictures in our manual. At first, put the converter with the top side on the DIN rail (1).
  • Page 9 To dismount the module from the DIN rail first open the clamp lever with a screwdriver on the bottom side (4). Hold the clamp lever opened while you lift the module from the DIN rail (5). Then remove the converter from the bar with while pulling it on the top side. Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 10: Dip Switch Settings And Terminals Of Resi-Mbusxlvl-Eth

    RESI® DIP switch settings and terminals of RESI-MBUSxLVL-ETH Function DIP Switch #1 Function DIP Switch #2 MODE Transparent- MODBUS/TCP to RTU Factory Config Illustration: DIP Switch settings for the RESI-MBUSxLVL-ETH converters Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 11 LINK This LED is on if Ethernet port is connected correctly to network DATA The LED shows the data flow on the Ethernet port Table: Description of connectors and LEDs of RESI-MBUSxLVL-ETH Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 12: Wiring Diagram Resi-Mbusxlvl-Eth

    RESI® Wiring diagram RESI-MBUSxLVL-ETH Ethernet 12-48Vdc MBUS MBUS MBUS MBUS meter meter meter meter load load load load 1.5mA 1.5mA 1.5mA 1.5mA Illustration: wiring diagram for RESI-MBUSxLVL-ETH converter Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 13: Resi-Mbusxlvl-Eth Operation Modes

    HI I AM HERE Ethernet Power 12-48Vdc MBUS MBUS MBUS MBUS meter meter meter meter load load load load 1.5mA 1.5mA 1.5mA 1.5mA HELLO WORLD\n HI I AM HERE Illustration: TRANSPARENT MODE on RESI-MBUSxLVL-ETH converters Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 14: Resi-Mbusxlvl-Eth Web Configuration

    RESI® 7 RESI-MBUSxLVL-ETH web configuration All our RESI-MBUSxLVL-ETH gateways have a build in web server to configure basic access to the Ethernet interface. Therefore open an Internet explorer and type in the configured IP address of the selected gateway. The standard configuration for STATIC IP (See DIP switch selection of RESI-MBUSxLVL-ETH gateways) is: RESI-MBUS24LVL-ETH: IP: 192.168.0.215 Mask: 255.255.255.0 Gateway: 192.168.0.1 Socket: 1024...
  • Page 15: Howto Setup Ip Address

    If you have problems, set the CFG DIP switch to ON and reboot the device. Wait for more than 30 seconds. The gateway will do a factory reset to the standard IP settings defined above. Don’t forget to put the DIP switch to OFF position after successful factory reset. Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 16: Howto Change Socket Number

    Socket number: Here you can select your desired socket number, you want to use for the Ethernet connection. Default for our converters is 1024, for MODBUS/TCP is 502 Please let the rest of the parameters unchanged. They are for expert usage only! Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 17: Howto Change User Name And Password

    Password: here you can enter a new password for accessing the web configuration. Don’t forget to save the new settings with the button SAVE below! Please let the rest of the parameters unchanged. They are for expert usage only! Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 18: Howto Restart The Module Via Ethernet

    RESI® HOWTO restart the module via Ethernet First select page Reboot. Then select button Restart Module to perform a software reboot. Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 19: Howto Configure The Serial Mbus Interface

    Returns the current UnitID for configuration, usually 254 ADDRESS: valid address between 0 and 255 #RESIPROTOCOL Host #RESIPROTO #RESIPROTO:<PROTOCOL> Answer Returns the current protocol for future use PROTOCOL: valid protocol type between 0 and 255 Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 20 HINT: The new settings are valid after a reboot of the gateway Host #RESIRESET #RESIRST Answer none Performs a module reset Host #RESIFACTORYRESET #RESIFRST Answer none Performs a reset of al parameters to factory default values and afterwards a module reset Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 21: Modbus Holding Register Table For Configuration

    17: 19200bd, even parity, 8 data bits, 1 stop bit 18: 38400bd, even parity, 8 data bits, 1 stop bit 19: 57600bd, even parity, 8 data bits, 1 stop bit HINT: You have to perform a reset to activate the new serial configuration! Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 22 RESI® Register Description 4x65523 While reading, the return value defines the type of the module: I:65522 H:0xFFF2 24: RESI-MBUS24LVL-ETH 48: RESI-MBUS48LVL-ETH MBUSxLVL-ETH 64: RESI-MBUS64LVL-ETH TYPE 4x65524 While reading, the return value defines the current software version: I:65523 H:0xFFF3 0xMMNN -> e.g. 0x100 means version 1.00...
  • Page 23 In normal mode, the STATE LED flashes with a period of 1 second. HINT: Only in the configuration mode, you can write new parameters to the configuration register. Don’t forget to reset the converter after configuration changes to make them active. Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 24: Initial Step: Select Transparent Or Modbus/Rtu Over Ethernet Mode

    Now you have done a factory reset to the IP standard settings and you have selected transparent mode. To configure the gateway use the software MODBUS POLL with the following parameters: Then select the function Setup/Read-Write Definition.. and configure the shown parameters. If successful you should see the following values: Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 25 RESI® Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 26: Initial Step: Select Modbus/Tcp To Modbus/Rtu Gateway Mode

    Now you have done a factory reset to the IP standard settings and you have selected MODBUS/TCP to MODBUS/RTU gateway mode. To configure the gateway use MODBUS POLL with the following parameters: Then select the function Setup/Read-Write Definition.. and configure the following parameters. If successful you should see the following values: Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 27 RESI® Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 28: Howto Change Gateway Configuration With Ascii Commands

    If not change the work mode with the Webpage or set DIP switch 3 MODE to OFF and DIP Switch 4 CFG to ON, wait for approx.. 30s until the Config-LED flashes very fast, the reset DIP Switch 4 to OFF. Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 29 Step 4: Before you select Open, check the terminal emulation page and change the parameters to the following parameters:  Step 5: Now click OPEN to establish a socket connection.  Step 6: Now request the current type and parameters of the gateway: Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 30 Step 8: Now we reopen the socket with the putty (Use Duplicate session), because the socket was closed with the reset of the gateway and we check the parameters for the MBUS line with:  Finished: Your gateway works with your new settings. Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 31: Howto Enter Configuration Mode

    Step 4: Don’t forget to reset the gateway either by shortly unplugging the power or by writing 1 to the RESET register. 4x65521 I:65520 H:0xFFF0 RESET SYSTEM  Finished: Your gateway works with your new settings. Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 32: Using Software Modbus Doctor To Configure

    When you start the software you will see the following screen: Now click on the drop down field RTU and select TCP/IP mode. The open the settings. The result will look like this: Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 33 Slave ID 254 for setup of gateway  Register 65535 to enter configuration mode  Length to 1, only one register should be read out Now open the web page of our gateway and select the page TTL1: Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 34 2. Now our gateway will initialize all parameters 3. Wait until the gateway has rebooted 4. Now the gateway works in MODBUS/TCP to MODBUS/RTU conversion mode 5. Set DIP switch 3 MODE to OFF 6. Wait until the gateway has rebooted Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 35 Second way: You can also change the behaviour with the web interface. Open the page TTL1 and select the following parameters: After you have changed the parameters, lick on save and then on "Restart Module" button in the web interface. Now you have activated the MODBUS/TCP to MODBUS/RTU conversion. Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 36 The displayed 1 indicates, that you are in configuration mode. Now we change the field Register to I:65520 and the field Length to 16 and click on READING. Be aware, that the software uses the protocol indexes starting with 0, not the MODBUS index of registers starting with 1! Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 37 READING. The Value should be 0, After that we enter the new value 10 into the field Value and then we click on the WRITING button: Then we change the field Register back to 65520 and the field Length to 16 and click on READING. We see the new settings: Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 38 1 into the register 65520 Value in the list and click on WRITING. The gateway will reboot. Now the gateway works in MODBUS/TCP to MODBUS/RTU mode and will convert incoming MODBUS/TCP requests into MODBUS/RTU requests on the serial line. Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 39 Set the DIP switch 3 MODE to OFF and DIP switch 4 CFG to ON, wait for approx.. 30 seconds, and reset both switches. It’s the same as if you change the parameters on the webpage. Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...
  • Page 40: Specifications

    RESI® 10 Specifications 10.1 Dimensions RESI-MBUSxLVL-ETH Illustration: dimension illustration in mm for RESI-MBUSxLVL-ETH Dimensions Enclosure dimensions L x W x H (mm) 35.8 x 90 x 58 Weight 90 g Colour Grey RAL7035 Material PA - UL 94 V0 Protection class...
  • Page 41: Drawing

    RESI® 10.2 3D drawing Illustration: Housing in 3D Date Page RESI-MBUSxLVL-ETH Manual Title: 05.10.2020...

This manual is also suitable for:

Resi-mbus64lvl-ethResi-mbus48lvl-ethResi-mbus24lvl-eth

Table of Contents