Fault Indications; Indicator Lamps; Troubleshooting - Asko D1996 Use And Care Manual

Asko d1996: user guide
Hide thumbs Also See for D1996:
Table of Contents

Advertisement

FAULT INDICATIONS

INDICATOR LAMPS

INDICATION
TROUBLE-SHOOTING PROGRAMME
It will be possible for you to locate the fault if the machine is not working properly. This facilitates the
work of the repair man and reduces repair time. To start the trouble-shooting programme, press the
Temperature selection button five time within 15 seconds. The lamps will flash alternately.
Then press the relevant symbol to see if the appertaining component according to the table below is
working. (Press Start to exit the test programme).
SYMBOL
TESTS
WATER SOFTENER INLET VALVE
WATER INLET VALVE
DETERGENT/RINSE-AID DISPENSER
HEATING ELEMENT
CIRCULATION PUMP
DRAIN PUMP
FAN MOTOR
TYPE OF FAULT
DOOR IS OPEN PREVENTING START OF THE SELECTED
PROGRAMME(NORMAL FOR THIS TYPE OF MACHINE)
ELEMENT MALFUNCTION
TOO MUCH WATER IN THE MACHINE
A SENSOR ERROR HAS OCCURRED
THE FOLLOWING WILL HAPPEN AFTER CLOSING THE
DOOR IF THERE IS NOTHING WRONG
WATER CAN BE HEARD ENTERING (ONLY MACHINES EQUIP
PED WITH WATER SOFTENER)
WATER CAN BE HEARD ENTERING
THERE WILL BE A CLICK, AND DETERGENT/RINSE AID WILL BE
DISPENSED
THE ELEMENT HEATS UP. N.B. DO NOT TOUCH THE ELEMENT
THE PUMP STARTS
THE PUMP STARTS
THE PUMP STARTS AND BLOWS OUT AIR BELOW THE LOWER
LEFT CORNER OF THE DOOR
ACTION
CLOSE THE DOOR
CONSULT SERVICE
SEE SETTING OF WATER /
DRAIN PUMP
CONSULT SERVICE
23

Advertisement

Table of Contents
loading

Table of Contents