"S
"
EALED
SERIES STOVES
The "Ermetica" series pellet stoves allow the
following possible installation alternatives:
ducted combustion air using a coaxial pipe to
consequently no fresh air vent is needed in the
room (Fig. 5.5 A, B=Air intake C, D=Flue gas
outlet);
connect the stove combustion air intake to the
fresh air opening using a special pipe (Fig. 5.6).
5.5 FLUE GAS EXHAUST
The stove operates with negative pressure in the
gas discharge must be airtight.
The stove must be connected to its own
ensuring adequate atmospheric dispersion of the
combustion byproducts.
conditions and bear the CE mark.
rock wool) or made using double wall steel pipes,
except for the initial vertical section inside the
room.
An initial vertical section measuring a minimum of
exhaust.
There should be at least three changes in direction
at the rear of the stove, using 45 or 90° angle
connectors or 'T' connectors.
Use always a 'T' connector with inspection cap on
It is necessary to connect a pipe at the bottom of the „T"
junction in order to discharge the smoke condensate
The maximum length of horizontal sections is 2-3
connected to:
a chimney used by other heat generators
air exhaust systems (range hoods, vents, etc.....)
even if these are ducted.
Shut-off or draught valves must not be used.
Combustion byproducts must be discharged
through the roof.
unsuitable discharge terminal, etc.) flue gas
exhaust may be less than optimum. In these cases,
38
INSTALLATION
C
cod. 00 477 2290 - 04/2015 - Palazzetti - PN - Italy
A
A D
B
B
B
B
Fig. 5.7a