Download Print this page
Nelson ROTATOR R2000WF Disassembly/Repair Instructions

Nelson ROTATOR R2000WF Disassembly/Repair Instructions

Advertisement

Quick Links

ROTATOR® FAMILY OF SPRINKLERS
Cap
Diffuser
Washer
Motor
Plate
Body
2TN Nozzle
Quick Change
Adapter
ALWAYS BE SURE
The Nozzle size is recommended
for the plate.
Operating pressures are between
40 and 65 PSI (2.8 to 4.5 BAR)
Proper assembly is essential to
product satisfaction.
R2000WF/LP
DISASSEMBLY/REPAIR INSTRUCTIONS
GENERAL DISASSEMBLY
1.
REMOVE THE SPRINKLER
from the ACME thread of
the quick change adapter.
2.
SEPARATE THE CAP FROM THE BODY
the release points (the words SQUEEZE) while
turning counter-clockwise. For easy removal, use
the #10689 Cap Removal Tool. Position the tool (as
shown on the right) to apply pressure to the words
SQUEEZE.
3. Use the #12260 2TN Nozzle Removal Tool to
REMOVE THE 2TN NOZZLE
the tool at the top of the R2000WF body and press
down. The nozzle should easily pop out.
WARNING: Always use the #12260 tool to remove a 2TN nozzle from a
R2000WF Rotator. Never use a stick, rod, or any other object to push on
the outlet of the 2TN nozzle to remove. This can easily damage the plate
bearing surface and cause rotation failure.
4.
REMOVE THE PLATE
by placing your fingers in the
open space in the cap (between the washer and
plate). Pull towards you until the plate pops up
away from the cap.
5.
REMOVE THE MOTOR
from the cap by fitting the
Motor Removal Tool #12215 onto the top of the cap.
(1)
Press on the outer ring of the motor removal
tool so it fits tightly against the cap.
the inner circle of the tool so the motor disengages
from the cap. Gently push the motor from the top to
completely remove it from the cap assembly.
Tel: +1 509.525.7660 / Fax: +1 509.525.7907 /
Cap Removal Tool
by squeezing
from the body. Place
Motor Removal Tool
(2)
Press on
nelsonirrigation.com
R2000WF Repair 2/2020
2TN Nozzle
Removal
Tool
2
1
1
/ info@nelsonirrigation.com

Advertisement

loading

Summary of Contents for Nelson ROTATOR R2000WF

  • Page 1 R2000WF Repair 2/2020 ROTATOR® FAMILY OF SPRINKLERS R2000WF/LP DISASSEMBLY/REPAIR INSTRUCTIONS GENERAL DISASSEMBLY REMOVE THE SPRINKLER from the ACME thread of Cap Removal Tool the quick change adapter. SEPARATE THE CAP FROM THE BODY by squeezing Diffuser the release points (the words SQUEEZE) while turning counter-clockwise.
  • Page 2 Assembly is now complete. WARRANTY AND DISCLAIMER: Nelson R2000WF Rotators are warranted for one year from the date of original sale to be free of defective material and workmanship when used within the working specifications for which the products were designed and under normal use and service.

This manual is also suitable for:

Rotator r2000lp