Download Print this page
Kasco PROF88 User Instructions

Kasco PROF88 User Instructions

Powered air purifying respirators
Hide thumbs Also See for PROF88:

Advertisement

Quick Links

Respirator composition chart:
Respirator
Part #
Code
0313072
0313143
1. DESCRIPTION
1.1 HELMET: It is composed of: a fiberglass shell covered with 3 coats of paint,
the last one of which, the most external one, is polyurethane; a polycarbonate
visor; a polyamide collar which closes efficiently and comfortably round the
operator's neck; a head-band adjustable from 53 to 63 cm (6-5/8 to 7-7/8 hat
size).
1.2 BLOWER UNITS (built into the helmet): They are located in a plastic housing
and are composed of a fan actuated by an electric micro motor.
1.3 BATTERY ASSEMBLY (built into the helmet): It is composed of: Nickel
Cadmium batteries connected in series.
1.4 BATTERY CHARGER: It is composed of: a stabilized battery charger and
includes electric cord and plug.
1.5 ZP3 FILTERS: made of finely pleated technical paper packed into plastic
housing .
1.6 AIRFLOW INDICATOR: It is composed of a transparent tube with indicator ball
inside. The indicator is needed to check the airflow performance of the
respirator it is supplied with, before each use.
2. TECHNICAL CHARACTERISTICS
2.1 HELMET:
- Shell : Fiberglass
- Face shield : Polycarbonate – Head suspension:
Polyethylene – Face shield gasket: polyethylene foam.
- Noise level < 80Db.
2.2 BLOWER UNITS
Type of unit
Type of
N. of
filter
filters
PROF88
ZP3
KOMPAT88
2.3 BATTERY ASSEMBLY
Type of
Type of
No. of
blower
battery
batteries
unit
connected
in series
PROF88
NI-CD
KOMPAT8
9
2,2Ah
8
- Cycle service life:
300 for discharges of 100%
1500 for discharges of 50%
2500 for discharges of 30%
2.4 BATTERY CHARGER
Type of unit
Charger Model
PROF88
NC-9
KOMPAT88
2.5 ZP3 FILTER (0601023):
HE – High Efficiency Particulate Air filter for powered, air-purifying respirators.
(See also label and Users' Instructions packed with filter).
When the HEPA filter is exhausted, an increase in drop pressure is registered on
the filter. This is indicated by a progressive diminishing of the airflow inside the
respirator.
USER'S INSTRUCTIONS
PROF88 – KOMPAT88
POWERED AIR PURIFYING RESPIRATORS
Helmet
Filter
PROF88
2 X ZP3
0302032
0601023
2 X ZP3
KOMPAT88
0302029
0601023
Voltage
Airflow at
20°C 60%
R.H. .-Battery
fully charged
- Volts
- Lpm
2
10,8
>170
Voltage
Terminal
Running
voltage
time at
under load
20°C
- Volts
- Volts
- Hours
10,8
9
>4
INPUT
OUTPUT
12,8V
110V 60Hz
400mA
Battery Charger
NC-9
0105082
NC-9
0105082
3. OPERATION
3.1 The blower units, powered by the built-in rechargeable batteries, take in air
through the filters and send it to the inside of the helmet. The helmet goes
into positive over pressure and the wearer breathes filtered air. Expired air is
expelled through the diaphragm valves.
4 USE
4.1 For the protection of the eyes and respiratory system of the wearer while
working in non I.D.H.L. environments containing dusts, fumes and mists.
4.2 LIMITATIONS
Do not use in atmospheres immediately dangerous to life or health.
Do not wear for protection against vapors and gas, carbon monoxide (CO),
natural gas and fumigants.
Do not use in closed environments (tanks, silos etc.).
Do not use for fire fighting.
Do not use in atmospheres containing less than 19.5% oxygen.
Do not use in explosive atmospheres.
Do not exceed max. use concentrations established by regulatory standards.
5. OPERATING INSTRUCTIONS
5.1a BATTERY RECHARGING USING NC-9 BATTERY CHARGER.
Plug the battery charger into mains.
Connect battery charger to the discharged battery.
Battery recharging is automatic. (Red led). Led turns GREEN when battery is
about 90% charged.
The battery charger may remain plugged into the fully charged battery with no
overcharge risk provided it is energized.
(See also instructions packed with battery charger)
Expected
micro motor
5.2 HELMET SET-UP
life
Remove protective film from visor. The film was applied to preserve the
transparency of the polycarbonate until the moment of use.
- Hours
Fit the helmet on head steadily.
800
Adjust head band fit.
5.3 DONNING INSTRUCTIONS:
DON PAPR IN AN UNCONTAMINATED ENVIRONMENT.
Approx.
Don helmet and tighten collar drawstring around neck by pressing the button
battery
and sliding it up the drawstring. The drawstring should be pulled as close as
life
possible around the neck to assure maximum closure but it should at all
times feel comfortable and not restrict breathing in any way.
2 years
for PROF88 respirator: Close lift-up visor.
or
300
cycles
5.4 AIRFLOW INDICATOR – Airflow checking test:
Make sure the Ni-Cad battery is fully charged.
Check that the filters are fitted into the helmet properly.
Open collar and keep it open throughout the test.
Switch the helmet ON.
Fit the airflow indicator over the right hand filter and position so that the
indicator is upright.
Check position of indicator ball:
Charging
If it rises above the 170 LPM indication line, the equipment is working
time
properly.
Hours
If it remains below the 170 LPM indication line, replace the filters and
 6
repeat the test.
Should the ball continue to stay below the 170 LPM line, recharge the
battery and repeat the test.
If the ball still remains below the 170 LPM line, replace the battery and
repeat the complete test.
 Fit the airflow indicator over the left filter and carry out the complete test as
above.
 Remove the airflow indicator.
The PAPR may be used only if both tests (both left and right sides) give positive
results. Do not use the PAPR with airflow indicators fitted over the filters. The
IST-USO-0905100
Rev. 1 – 11/01/2017
IDP 109
Page 1 of 2
Airflow
indicator
NIOSH APPROVAL
0806010
TC-21C-633
0806010
TC-21C-633

Advertisement

loading

Summary of Contents for Kasco PROF88

  • Page 1 - Volts - Volts - Hours times feel comfortable and not restrict breathing in any way. 2 years PROF88  for PROF88 respirator: Close lift-up visor. NI-CD KOMPAT8 10,8 >4 2,2Ah cycles 5.4 AIRFLOW INDICATOR – Airflow checking test: ...
  • Page 2 LIMITED PRODUCT WARRANTY KASCO, as manufacturer, warrants to the original purchaser, each product of its own manufacture, for a period of one year from its date of shipment from the factory, to be free from defects in material and workmanship under normal use and service.
  • Page 3 KASCO Via  Romania 12 ‐ 42124 Reggio Emilia ‐ ITALY Tel: +39 0522 308232 ‐ Fax: +39 0522 939803 THESE RESPIRATORS ARE APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS: RESPIRATOR COMPONENTS CAUTIONS AND PROTECTION LIMITATIONS 21C-633 ABCFIJLMNOP 21C-627 X ABCFIJLMNOP 1. PROTECTION HE ‐ High efficiency particulate air filter for powered air purifying respirators 2. CAUTIONS AND LIMITATIONS A‐Not for use in atmospheres containing less than 19.5 percent oxygen. B‐Not for use in atmospheres immediately dangerous to life or health. C‐Do not exceed maximum use concentrations established by regulatory standards. F‐Do not use powered air‐purifying respirators if airflow is less than four cfm (115 lpm) for tight fitting facepieces or six cfm (170 lpm) for hoods and/or helmets. I‐ Contains electrical parts that may cause an ignition in flammable or explosive atmospheres. J‐Failure to properly use and maintain this product could result in injury or death. L‐Follow the manufacturer's User's Instructions for changing cartridges, canisters and/or filters. M‐All approved respirators shall be selected, fitted, used and maintained in accordance with MSHA, OSHA, and other applicable regulations. N‐Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer.

This manual is also suitable for:

Kompat8803130720313143