Plymovent CONTROLPRO Installation Manual

Plymovent CONTROLPRO Installation Manual

Control panel with separate hmi
Hide thumbs Also See for CONTROLPRO:

Advertisement

Quick Links

Control panel with separate HMI
CONTROLPRO
EN
Installation manual
www.plymovent.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CONTROLPRO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Plymovent CONTROLPRO

  • Page 1 Control panel with separate HMI CONTROLPRO Installation manual www.plymovent.com...
  • Page 2: Table Of Contents

    Thus the manufacturer cannot be held responsible for any damage resulting from the application of this publication to the version actually delivered to you. This publication has been written with great care. However, the manufacturer cannot be held responsible, either for any errors occurring in this publication or for their consequences. 0000112606/010720/A ControlPro...
  • Page 3: Preface

    General description Mounting frame - Plymovent FRAME SIF specific type depends on the ControlPro of Plymovent is an intelligent control panel with selected extraction fan and separate HMI, that is supplied including the required configuration connection cables. This system controls the fan and the...
  • Page 4 Working range: 0-4000 Pa (0-16 in. WG) 1.6.2 ControlPro/HMI Ambient temperature: Full integration of communication between the HMI and the Plymovent VFD/ - min. 0°C (32°F) Panel (frequency inverter) through an RS-485 cable. Including main switch to - nom.
  • Page 5: Product Description

    PC board (master board) Bottom plate with cable glands SAFETY INSTRUCTIONS General The ControlPro is delivered as part of a filter system MDB or SCS of Plymovent. The safety instructions written in the related manuals apply to the ControlPro as well.
  • Page 6 (4) for the pressure tubes Fig. 4.1 Connection cables Mounting ATTENTION Do not expose any component of ControlPro to vibrations or heat radiation. You must install the Panel and HMI at a clearly visible and Fig. 4.4 Bottom plate accessible position.
  • Page 7 Table I on page 21 gives an overview of the necessary and optional cables that you need to install the system. 17. Recommended cable specifications; use cables with a max. wire diameter 1,5 16. Max. 10 mm² (AWG 16) 0000112606/010720/A ControlPro...
  • Page 8 Depending on the selected fan control equipment, you can connect the fan in two different ways: - Plymovent VFD/Panel (frequency inverter) by RS-485 cable - direct fan start by conventional cables Connect the selected fan control equipment in accordance with the instructions below.
  • Page 9 Power Light tower the RS-485 cable to the frequency inverter. 1 2 3 4 5 6 For more information about the Plymovent VFD/ Cable #15 Panel, refer to the Danfoss documentation that is supplied with the product. Analog Filter Pressure...
  • Page 10 Cable SlaveBoard  SlaveBoard, including: - conduit - conduit connectors M20 + nuts Tube clamp + screw (CAN IN) Fig. 4.14 Connection of SlaveBoard 22. Supplied with the Panel  SlaveBoard cable (#2) 23. Address configuration pos. 1-4: according to number 1 0000112606/010720/A ControlPro...
  • Page 11 24. 2 per SlaveBoard 25. 1 tube clamp in case of a filter module MDB-BM/2 26. Supplied with Panel  SlaveBoard cable (#2) 27. Both supplied with Panel  SlaveBoard cable (#1) 28. The red module on the PC board 0000112606/010720/A ControlPro...
  • Page 12 Input signals (options) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 If desired, you can connect the ControlPro to a start/stop Digital input 6-12 signal and/or an alarm signal from an external device...
  • Page 13 External start/stop signal IN 9 IN 2 BTN lter cleaning IN 6 Fire alarm (ShieldControl) IN 10 Compressed air switch 32. In case of Plymovent VFD/Panel IN 2 BTN lter cleaning IN 6 Fire alarm (ShieldControl) IN 10 C IN 3...
  • Page 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 [page 7] ControlPro is SHIELD-ready. You must connect the following components to the Panel (refer to paragraph 1.3.2): input IN 7...
  • Page 15 • Connect the two pneumatic hoses to the corresponding + compressed air tank. and – (A+B) on the junction box. Fig. 4.28 • Remove the cover caps from the + and – (A+B) on the lower filter module. 0000112606/010720/A ControlPro...
  • Page 16: Commissioning

    - LED off: system is off - LED blinking: system is starting up - LED on: system is ready 38. In case of Plymovent VFD/Panel or other type of frequency inverter 39. Indication: the white LED on the Panel is blinking 0000112606/010720/A ControlPro...
  • Page 17: Maintenance

    - LED on: fan is running system manually. Yellow LED | WARNING - LED off: no problem Refer to the online user manual ControlPro for - LED on : refer to the HMI for the cause of the warning extensive explanation: D Red LED | ALARM www.plymovent.com/manuals/controlpro...
  • Page 18: Troubleshooting

    Rotary switch 0-1 6.1H) 0000113558 Indicator light yellow 24V Black screen HMI does not Loose Tighten the HMI 0000113559 PCB main board ControlPro function connection cable to the CAN connector (refer to 0040900180 Main switch 25A Fig. 4.7B+C) 0324000300 Indicator light white 24V...
  • Page 19: Ce Declaration

    CE DECLARATION CE Declaration of Conformity for machinery We, Plymovent Manufacturing B.V., Koraalstraat 9, 1812 RK Alkmaar, the Netherlands, herewith declare, on our own responsibility, that the product: - ControlPro which this declaration refers to, is in accordance with the...
  • Page 20 ANNEX Fig. I Dimensions Panel Fig. III SlaveBoard | PC board CAN IN CAN OUT 17.1 15.7 15.7 16.7 Fig. II SlaveBoards Fig. IV Connection sequence SlaveBoards 0000112606/010720/A ControlPro...
  • Page 21 VENTILATEUR MARCHE/ARRÊT DÉCOLMATAGE DE FILTRE MODE MAINTENANCE ARRANQUE/PARADA VENTILADOR LIMPIEZA DE FILTROS MODO SERVICIO Fig. VI ControlPro/Panel 0000103139 0000113559 0000113558 0324000310 0000112513/A 0324000300 0324000320 0328050320 0328050300 0360000060 0000103141 0040900180 Fig. VII ControlPro/HMI Fig. VIII Control/SlaveBoard 0000112777 0000113561 0000113560 0000112606/010720/A ControlPro...
  • Page 22 Sliding valve 1 closed open IN 8 Sliding valve 2 closed open IN 9 Fan alarm alarm normal IN 10 Compressed air switch normal alert IN 11 External alarm signal normal alert IN 12 Dustbin level switch full not full 0000112606/010720/A ControlPro...
  • Page 23 0000112606/010720/A ControlPro www.plymovent.com...