ViM BATE-R010 Instruction Manual

ViM BATE-R010 Instruction Manual

Circular electrical heater with built-in control for external 0-10v signal
Hide thumbs Also See for BATE-R010:

Advertisement

Quick Links

INSTRUCTION MANUAL
INSTALLATION | WIRING | COMMISSIONING | MAINTENANCE |
I S O 9 0 0 1
ISO 14001
Q u a l i t é
Environnement
AFNOR CERTIFICATION
AFNOR CERTIFICATION
BATE-R010
Circular electrical heater with built-in control
for external 0-10V signal
NT00000592-BATE-R-010-AN-191114

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BATE-R010 and is the answer not in the manual?

Questions and answers

Summary of Contents for ViM BATE-R010

  • Page 1 INSTALLATION | WIRING | COMMISSIONING | MAINTENANCE | I S O 9 0 0 1 ISO 14001 Q u a l i t é Environnement AFNOR CERTIFICATION AFNOR CERTIFICATION BATE-R010 Circular electrical heater with built-in control for external 0-10V signal NT00000592-BATE-R-010-AN-191114...
  • Page 2: Table Of Contents

    INSTALLATION ..........................4 Characteristics .......................... 4 Assembly ..........................4 ELECTRICAL CONNECTION ......................5 BATE-R010 Single-phase - Power < 4kW ................5 4.2 BATE-R010 Single-phase - Power ≥ 4kW ................6 BATE-R010 Three-phase - Power < 18kW ................6 BATE-R010 Three-phase - Power ≥ 18kW................7 COMMISSIONING AND MAINTENANCE ..................
  • Page 3: Safety Instructions

    1.2 Safety instructions Put on appropriate PPE (Personal Protective Equipment) before any work, If work has to be carried out on the device, cut off the power supply on the main circuit breaker and make sure that nobody can accidentally turn it back on, Before operating the equipment, check the following points: • Make sure that the device does not contain any foreign bodies, •...
  • Page 4: Installation

    INSTALLATION 3.1 Characteristics Min. air Max. air Dimensions (mm) Power Current Weight Designation volume volume (kg) Single-phase 230V power supply BATE R010 125 600W Single-phase 276 373 195 48,5 276 373 195 48,5 BATE R010 125 900W Single-phase BATE R010 125 1 200W Single-phase 1 200 276 373 195 48,5 BATE R010 160 2 100W Single-phase...
  • Page 5: Electrical Connection

    • Max cable diameter for power supply: 10mm 16mm ≤ 4,5kW ˃ 4,5kW Mono 230V ≤ 15kW ˃ 15kW Tri 400V ELECTRICAL CONNECTION 4.1 BATE-R010 Single-phase - Power < 4kW BATE-R010 <4kW 1 phase power supply 230V 50Hz air ow according to NF C 15-100 standard controller 50°C auto θ...
  • Page 6: Bate-R010 Single-Phase - Power ≥ 4Kw

    4.2 BATE-R010 Single-phase - Power ≥ 4kW BATE-R010 1 phase power supply ≥4kW 230V 50Hz air ow according to NF C 15-100 standard controller 50°C auto θ reset Safety thermostat manual 100°C reset θ Command signal 0...10VDC Equipment Included Optional...
  • Page 7: Bate-R010 Three-Phase - Power ≥ 18Kw

    4.4 BATE-R010 Three-phase - Power ≥ 18kW BATE R010 3 phases power supply 400V 50Hz air ow according to NF C 15-100 standard controller 50°C auto θ reset Safety thermostat 100°C manual θ reset Command signal 0...10Vcc In any case, it must not be possible to shut off the fan without the heater shutting off beforehand (MCR1- type post-ventilation delay if necessary) or at the same time (to be avoided),...
  • Page 8: Fault Resolution

    Les prés de Mégy Sud – SOUDAN - CS 60120 - 79401 ST MAIXENT L’ECOLE CEDEX Tel.: 05 49 06 60 38 or 05 49 06 60 25 – Fax: 05 49 06 60 36 sav@vim.fr - www.vim.fr NT00000592-BATE-R-010-AN-191114...