10 Servicing and maintenance
10.1 Draining the condensation
Over time, condensation will collect in the air conditioning unit's tank. If the tank is
full, the unit stops and Ft (= full tank) appears on the display.
Draining the condensation manually:
>
Remove the plug on the air conditioning unit from the wall socket.
>
Place a suitable container under the lower condensation drain (9, page 36).
>
Remove the drain cap and let all the water drain into the collection vessel.
>
When the water has drained off, put the cap back on the condensation drain.
>
You can then put the air conditioner back into operation.
Automatically drain the condensation continuously:
In dehumidifier mode, the condensation must be continuously drained to the
outside. The upper condensation drain (10, page 36) is provided for this.
>
Remove the plug on the air conditioning unit from the wall socket.
>
Place a suitable container under the upper condensation drain (10, page 36).
>
Remove the drain cap and attach a suitable hose to the drain connection.
>
The hose should now be directed vertically downwards into the collection
vessel. Be careful not to kink the hose.
>
Put the air conditioner back into operation and activate the dehumidifier
mode.
In cooling mode, the upper condensation drain must be closed to ensure
efficient operation.