Operating instructions for the machine
A
2. Technical specifications
• fonts available:
- continuous action (font 0)
- dot by dot (font 1-3)
- size: from 0.5 mm (0.02 in) to 45 mm (1.772 in) with increments of 0.1 mm (5/1000 in)
- characters: those included in the basic multilingual diagram of the Unicode standard (ISO 10646)
• dates, counters, batch numbers, shift codes, logos...
If the room temperature is greater than 30
marking (stroke force > 80%), pause regularly in order to avoid overheating the
electronics and the screen or order a ventilator kit (ref. 73066).
Example:
Operating factors: 33% (marking: 10 s / pause: 15 s):
=> temperature = 30
=> temperature = 45
3. Physical characteristics
• dimensions (L x w x h): 325 mm (12.795 in) x 211 mm (8.307 in) x 408 mm (16.063 in) (excluding side handle)
• weight: 5.5 kg (12.125 lb)
• marking area: 80 mm (3.15 in) x 30 mm (1.181 in)
Ref. 72523 - XM700_en_B
0
0
0
C (86
F): restrict continuous operation to 50 minutes.
0
0
C (113
F): restrict continuous operation to 35 minutes.
0
C (86
F) and if performing very deep
B
8/23