FAILURE CODE
(*) See the section regarding maintenance and cleaning of your machine.
PROBABLE
FAILURE
The water
level in your
machine is
below heater.
The pressure
of your water
supply may
be low or
unstable.
The pump
has failed or
the pump filter
is obstructed.
There is an
excessive
amount of
water in your
machine.
35
CORRECTIVE MEASURES
Turn on the tap to the end. Water
supply may be cut, check it. If the
problem still exists, your machine
will automatically stop after a
while. Unplug your machine, turn
off the tap and consult your
nearest authorized service
provider.
Clean the pump filter. If the
problem persists, consult your
nearest authorized service
provider.(*)
Your machine will automatically
drain the water. After your
machine has completed the
draining process, shut down your
machine and unplug. Close the
tap and consult your nearest
authorized service provider.