Summary of Contents for ACP Amana Commercial Xpress IQ ARX Series
Page 1
Ventless Submittal Information ARX & MRX SERIES 225 49 Ave. Dr. SW, Cedar Rapids, IA 52404 800-233-2366, 319-368-8120, Fax: 319-368-8198 www.acpsolutions.com...
What if local inspector questions ventless installation? ACP, Inc. will assist with approvals. In general you need to notify the appropriate local agency having jurisdiction (AHJ) and prepare a submittal package including menu items. ACP, Inc. can provide additional information to assist and guide you through the process.
Page 5 of 26 COMMERCIAL ELECTRIC COOKING APPLIANCES - UL 197 MARCH 17, 2010 PART 1 - ALL APPLIANCES INTRODUCTION 1 Scope 1.1 These requirements cover commercial electric cooking appliances rated 600 volts or less, intended for indoor use, and intended f o r use in accordance with the National Electrical Code, NFPA 70. 1.2 These requirements cover coffee makers, conductive cookers, food warmers, fryers, griddles, steam kettles, steam cookers, nut warmers, popcorn machines, ranges, utensil warmers, and other appliances f o und in commercial kitchens, restaurants, or other business establishments where food is dispensed.
Page 6
Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. ACP Inc. ACP Inc. Applicant: Manufacturer: 225 49th Ave.
Page 7
Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. ACP Inc. ACP Inc. Applicant: Manufacturer: 225 49th Ave.
NON-CONFORMANCE LETTER REPORT www.intertek.com 20-Mar-2018 Intertek Report No. 103443931COL-001A Intertek Project No. G103443931 Patrick Henry Ph: (319) 368-8178 ACP Inc. Fx: (319) 368-8194 225 49 Ave. Dr. SW Cedar Rapids, IA 52404 Email: PHenry@acpsolutions.com EPA 202 Emissions Testing Performance Compliance – Commercial Subject: Convection/Microwave Oven Cooking Appliance –...
Page 9
Page 9 of 26 ACP Inc. Intertek Report No.: 103443931COL-001A NON-CONFORMANCE LETTER REPORT SECTION 3 PROJECT STATUS & ACTION Issuance of this letter report completes the scope covered by Intertek Project No. G103443931. If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact your dedicated Intertek Project Manager, Emilie Engesether, emilie.engesether@intertek.com.
Page 10 of 26 ACP, Inc. Guidelines for Ventless Use The ARX / MRX High Speed Oven conforms to UL 923, EPA202 and NFPA96. The UL 923 standard covers the electrical and product safety standard. The EPA202 and NFPA96 standard covers the low particulate matter emissions standard to which we conform. While both standards cover different aspects of the oven, they both overlap as it relates to grease and fire handling.
Page 11 of 26 ARX2 / MRX2 Estimated Heat Load Calculations ARX2/MRX2 (single phase) Parameters Operating Time 12 Hours Energy Costs $0.11 KWHr Idle Time 2 Hours Cook Cycles/Daily Typical Cook Time 60 Seconds Balance of Time Power Data Cost/Day Time (Minutes) (Watts)
Page 12
Page 12 of 26 ARX1 / MRX1 Estimated Heat Load Calculations ARX1/MRX1 (single phase) Parameters Operating Time 12 Hours Energy Costs $0.11 KWHr Idle Time 2 Hours Cook Cycles/Daily Typical Cook Time 60 Seconds Balance of Time Power Data Cost/Day Time (Minutes) (Watts)
Page 14
H 25” (635) W 18” (457) D 35 1/2” (902) Shipping Carton Safety and Sanitation Weight This ACP, Inc. product meets and exceeds safety and Model# Product Weight Ship weight (approx.) sanitation standards set for commercial microwave ARX2 134 lbs. (61 kg) 152 lbs.
Page 15
Safety and Sanitation This ACP, Inc. product meets and exceeds safety and sanitation standards set for commercial microwave ovens by UL, ETL, NSF, CSA, FDA, ETL EU and CE *Only shipped in U.S.A.
520°F (270°C). always use recommended cleaning supplies: 1. Oven must be plugged in. Damp towel, plastic scouring pad, ACP Oven Cleaner (CL10) (Screen will power on to “Standby mode” within and ACP Oven Shield Protectant (SH10). approximately 30 seconds.) 2.
Page 18
Microwave and Fan can be set to power levels between 0-100%. Note: You may also create and edit recipes using the ACP Programming Application. 1. After oven has preheated touch blue menu icon. Note: To guarantee that oven reaches the desired temperature before the start of cook cycle, enable “Preheat Warning”...
Page 20
Remove USB Flash Drive. Settings and menu items will be loaded on USB Flash Drive and ready to share or open in ACP Programming Application . Open Menu in ACP Programming Application Note: For more comprehensive instructions, see ACP Programming Application User Guide online 1.
Page 22
2. Scroll down and touch to select “User Options.” 3. Use this menu to modify oven settings. Touch the left arrow to return to the menu after making each change. Note: You may also make user options changes using the ACP Programming Application. STANDARD DEFAULT PER MODEL User Option ARX &...
Page 27
Getting Started: 1. Launch the application • Windows: Open “ACP Remote Programming Interface” from your Program Files, or the Start Menu shortcut • Mac OS: Open the “ACP_Application.app” file 2. Start a New menu from scratch (a), or Open an existing menu (b): a.
Page 28
Note: The temperature set in the User Options section will be the default when creating a new menu item Note: The default logo for the standby screen is the ACP, Inc. logo. Customize it and add your own logo by selecting the “Add Logo to Startup”...
Page 31
Edit an Existing Recipe 1. Open the ACP Programming Application from your computer. 2. Select “File,” then “Open.” Navigate to the location of your menu file and open it. 3. Double-click to open the folder containing the recipe. 4. Click on a recipe to edit the recipe name, image or cook settings.
Page 32
Via WiFi/Ethernet Do you have a .mxp menu file which you’d like to load onto an oven with an older firmware version? ● ACP strongly recommends updating the oven to the latest and greatest version of firmware. Visit acpsolutions.com/oven-programming/ to learn more and download .
Page 33
520°F (270°C). always use recommended cleaning supplies: 1. Oven must be plugged in. Damp towel, plastic scouring pad, ACP Oven Cleaner (CL10) (Screen will power on to “Standby mode” within and ACP Oven Shield Protectant (SH10). approximately 30 seconds.) 2.
Page 34
Microwave and Fan can be set to power levels between 0-100%. Note: You may also create and edit recipes using the ACP Programming Application. 1. After oven has preheated touch blue menu icon. Note: To guarantee that oven reaches the desired temperature before the start of cook cycle, enable “Preheat Warning”...
Page 36
Remove USB Flash Drive. Settings and menu items will be loaded on USB Flash Drive and ready to share or open in ACP Programming Application . Open Menu in ACP Programming Application Note: For more comprehensive instructions, see ACP Programming Application User Guide online 1.
Page 38
2. Scroll down and touch to select “User Options.” 3. Use this menu to modify oven settings. Touch the left arrow to return to the menu after making each change. Note: You may also make user options changes using the ACP Programming Application. STANDARD DEFAULT PER MODEL User Option ARX &...
Page 39
During this time the screen may blank out for 30 seconds or longer. Continue to wait. o The screen will blink, then a few seconds later the ACP logo will appear. Underneath will appear the word “Updating” along with a progress bar. Continue to wait. Note: Do not remove the USB stick until AFTER the next reboot is completed.
Page 40
Please note: for ovens with firmware 3.1.0 and older installed, use of certain types of USB flash drives may result in issues when attempting to update to newer firmware. ACP recommends using a USB flash drive with MLC-type flash memory. Recommended flash drives include:.
Need help?
Do you have a question about the Amana Commercial Xpress IQ ARX Series and is the answer not in the manual?