Problem E : The METOSWR has toppled over, type with pneumatic tyre
wheels.
Cause E
: - Carelessness when moving
Solution
: 1. Switch off the METOSWR with the main switch
8.5

Dismantling

When your METOSWR is defective to such an extent that it must be dismantled,
you must take it to your supplier or another company that specialises in
dismantling vehicles. Never take your METOSWR to a scrap metal merchant or
dump. The METOSWR must be dismantled and chemical parts disposed of
(liquids and oil).
Dispose of oil as chemical waste.
Translated user manual (EN-V1)
- Slippery concrete path
- Unstable surface
- Too heavy (long) hose used
- Winding up 'over the top' in combination with too long a
hose
- Handlebar pull handle locking clip not used
2. Remove the plug from the socket
3. Clean the concrete path, restore grip
4. Use the METOSWR only on a stable surface
5. Use a shorter hose
6. Wind up from the bottom
7. Always use the handlebar pull handle locking clip
8. Locate the cause and solve (remove)
9. Check according to chapter 7