RDA-ENC6 and RDA-ENC12 power distribution and line input references
FIG. 14 shows the power distribution and line input references for the RDA-ENC6 and RDA-
ENC12 line inputs.
RDA-ENC6
Line input 1 feeds dimmers 1 and 4
Line input 2a feeds dimmer 5
Line input 2b feeds dimmer 2
Line input 3 feeds dimmers 3 and 6
FIG. 14 RDA-ENC6 and RDA-ENC12 power distribution and line input reference references
Installing RDM Modules into an Enclosure
Installing any of the RDM modules is an easy task. The individual modules are shipped with the
four mounting screws enclosed.
To prevent possible personal injury or death, cut off power to the enclosure at the
breaker box before attempting to install any AMX Lighting modules.
FIG. 15 illustrates the inside of an RDA-ENC6 enclosure and the mounting slots. The modules are
positioned in the appropriate slot and secured using the supplied screws.
Radia Lighting Control System
RDA-ENC12
Line input 1 feeds dimmers 1 and 4, 7 and 10
Line input 2a feeds dimmer 5 and 11
Line input 2b feeds dimmer 2 and 8
Line input 3 feeds dimmers 3 and 6, 9 and 12
Installation
11