Rda-Enc6B 120/208 Vac Line Input (Three Phase); Rda-Enc6B Three Phase Line Input Connector Reference - AMX RDA-ENC2 Instruction Manual

Amx rda-enc2 dimmer enclosures: user guide
Hide thumbs Also See for RDA-ENC2:
Table of Contents

Advertisement

Installation
5. Connect load lines from the electrical devices to the Load terminals. Load 1 applies to dimmer
1, Load 2 applies to dimmer 2, and so on.

RDA-ENC6B 120/208 VAC line input (three phase)

FIG. 12 shows a 120/208 VAC three-phase (4 W + G) wiring diagram for the RDA-ENC6B line
input terminal block.
FIG. 12 RDA-ENC6B 120/208 VAC three-phase (4 W + G) wiring diagram

RDA-ENC6B three phase line input connector reference

FIG. 13 shows a sample RDA-ENC6 three phase (4 W + G) line input connector and dimmer
references.
FIG. 13 RDA-ENC6B three-phase (4 W + G) line input connector and dimmer references
10
1
2a
2b
3
1
2a
2b
3
Line input 1 feeds dimmers 1 and 4
Line input 2a feeds dimmer 5
Line input 2b feeds dimmer 2
Line input 3 feeds dimmers 3 and 6