NBE BRAWN MIXER BTR 1 Series Operation And Maintenance Manual page 23

Table of Contents

Advertisement

Lubricator Service Interval
The Automatic lubricator should be inspected approximately
every 6 months. At the end of the lubrication period the pis-
ton becomes clearly visible through the clear nylon discharge
indicator cap located at the bottom of the PERMA® canister
(Figure 1); this helps indicate that the lubricant has been fully
discharged at which time the lubricator should be replaced.
When operating the gear unit 8 hours/day or less a replace-
ment interval of 12 months or 1 year is possible. Ambient
temperature will influence the discharge rate and may ex-
tend or shorten the replacement interval.
Ambient Considerations
The grease discharge rate is affected by the ambient tem-
perature. PERMA® indicates that the lubricator contents will
dispense for a 12 month period when the average tempera-
ture is 20 °C (68 °F). Grease dispensing rates depend primarily
on average ambient conditions and not extreme highs and
lows. Lower ambient temperatures will lead to slower dis-
pensing rates and higher ambient temperatures will lead to
faster dispensing rates.
Average Ambient Temperature
0 °C (32 °F)
10 °C (50 °F)
20 °C (68 °F)
30 °C (86 °F)
40 °C (104 °F)
♦ Values are approximate.
Discharge can also be influenced by type of lubricant, vi-
bration, and by the mating connecting parts in the lubrica-
tion system.
Activating the Automatic Lubricator
1. Loosen and remove the M8x16 assembly socket head cap
screws (1251).
2. Carefully remove the protective cover (1252) installed over
the automatic lubricator (1250-1).
3. Screw the activation screw (1250-2) into the automatic
lubricator (1250-1) and twist the ring-eyelet until it
reaches its breaking point.
4. Re-fit the cartridge cover (1250-1) and re-install and
tighten the assembly screws (1251).
5. Mark the activation date on the adhesive label that is
provided.
NORD Gear Limited
Toll Free in Canada: 800.668.4378
01.31.17
AUTOMATIC LUBRICATOR
RETAIN FOR FUTURE USE
Discharge Period Months ♦
>18
18
12
6
3
Figure 2 - Activating the Automatic Lubricator
Attention!
Screw in the activation screw until the lug breaks off
before commissioning the gear unit.
Dispensing time: 12 Months
Activation Date
Month
1 2 3 4 5 6 7 8 9 10 11 12
Label 1250-1 1250-2
Ring
Eyelet
1250-1 Automatic Lubricator
1250-2 Activation Screw
1251
Socket Head Cap Screws
1252
Protective Cover
Toll Free in the United States: 888.314.6673
U45250 - 2 of 3
Year
11 12 13 14 15
1252 1251 1250-2
NORD Gear Corporation
www.nord.com/docs

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brawn mixer btr s series

Table of Contents