Wireless Zone Types; Fault Annunciation - ADEMCO VISTA 4140XMPT2 Installation Instructions Manual

Partitioned security system with scheduling
Hide thumbs Also See for VISTA 4140XMPT2:
Table of Contents

Advertisement

Note On RF Keys
5800 series RF keys can be used to arm and disarm the system. These
(5801, S803, etc.)
transmitters include the 5801, 5803, and any other 5800 series transmitter if
programmed for one of zone type responses 20-22. These transmitters are tied
,
to a user in order to provide a record of who armed or disarmed the system.
Because of this, an RF button will not armor disarm a system unless it has been
w
assigned to a user, which is done during the "add a user" function (see Add A
User
Code section). In addition, when the user is deleted from the system, the
key is deactivated. To test whether the keys are assigned to users or not, use the
test mode. When the appropriate button is pressed, the corresponding zone will
be displayed on the console and will remain there until test mode is terminated.
Wirelees Zone Types
Each RF zone can be programmed to respond as any zone type such as
ENTRY/EXIT, INTERIOR, PERIMETER, etc. (see the ZONE TYPES section for a
complete explanation of each zone type).
Desired alarm responses for 5700 series devices are as follows:
ZONE TYPE
TRANSMITTER ID #
Entry/Exit Burg
1 through 47 *
Perimeter Burg
1 through 47
Interior Burg
1 through 47
32 through 47 * (5775)
Fire
46 through 63
48 through 55 "' (5706)
24 Hour Panic
46 through 63*
(silent or audible)
62 or 63 ** (5701)
Day/Night Burglary
1 through 47
24 Hour Auxiliary
1 through 47 *
NOTES:
Note that zones 1-63 can be used, but have the following limitations: Transmitters set
for zones 48-55 will transmit once every 12 seconds while the zone is faulted.
Transmitters set for zones 56-63 will transmit once every 3 seconds while faulted.
These two ranges of zone numbers could adversely affect transmitter battery life.
Transmitters set for an ID of 32 through 47 will have a 3 minute lock-out between
*
transmissions. Use this last range of zone ID numbers for sensors protecting
frequently used doors or windows to conserve battery life.
**
Transmitter IDs 48 through 55 have highest signal priority.
*•* Transmitter IDs 62 and 63 are unsupervised to allow removal of the 5701 off premises
.- signal prioriiy is lower than that of fire, but higher than burglary.
Advlsorles
1. Do not place transmitters on or near metal objects. This will decrease range
and/or block transmissions.
2. Place the receiver in a high, centrally located area for best reception. Do not
place receiver on or near metal objects.
3. For maximum range, the RF receiver must be at least 10 feet from the Control
panel or any remote consoles to avoid intederence from their microprocessor.
UL NOTE: For UL Household Burglary Installations,
wired
loops
connected
to these
devices
cannot
exceed
3 feet.
4.
If dual receivers are used:
A.
Both must be at least 10 feet from each other, as well as from the Control
panel and remote consoles.
B. The
house IDs must be the same.
C. Using two Receivers does not increase the number of transmitters the
system can suppofi (83 transmitters, plus a wireless keypad).
Fault Annunciation
Since the polling loop and the RF receiver(s) are shared among the 8 partitions,
the scheme for annunciating their failure is as follows:
Respective faults (for zones 88-91 & 97) will report as trouble conditions only, and
as such, should be assigned either zone type 00 if no annunciation is desired, or
zone type 05 if annunciation as trouble condition is desired. If the polling loop or
RF link fails, the corresponding zone number will display a trouble condition for
each partition that uses the device that failed, In addition, all zones associated with
that device will indicate a fault condition. The trouble condition will not interfere
~
with the ability to arm the parlition, but the faults must first be bypassed.
NOTE: 5800 series transmitters
have built-in tamper protection
and will
annunciate as a
"CHECK"
condition unless field 24 is disabled.
-20-

Advertisement

Table of Contents
loading