24 VDC
24 VDC is required to power the interface. Two terminals are
provided and accept 16 AWG (1.5 mm
1.
2.
3.
4.
Ethernet
An RJ45 receptacle provided for Ethernet connection is located on the
bottom of the interface. This connection complies with the EIA/TIA
standard.
Power Up
Once the Expansion Bridge is connected to the EchoConnect station bus
and power is applied, the power LED will indicate steady blue and the
display will power on.

User Interface

Display and Buttons

On initial power up, the display will show Expansion Bridge (which is the
device name), its default IP address (10.101.19.101), and "Connected to:
Processor Name " displays when the device is connected to a Paradigm
system, alternatively "Not Connected" displays when no active
connection is found.
The display automatically sleeps after two minutes of inactivity and wakes
again with any button press.
Expansion Bridge
Insert the black wire (typical) into the negative (-) terminal and
tighten the screw firmly onto the wire.
Insert the white wire (typical) into the positive (+) terminal and
tighten the screw firmly onto the wire.
Insert the ESD ground wire into the last terminal (identified with a
ground symbol) and tighten the screw firmly onto the wire.
Repeat for any additional segments.
Strip 5/16" (8 mm) of insulation from the bare end
of each wire.
Loosen the two screw terminals on the 24 VDC terminals.
Insert the negative (or common) wire (black wire typical) into the
negative (-) terminal and tighten the screw firmly onto the wire.
Insert the positive (+) wire (red wire typical) into the positive (+)
terminal and tighten the screw firmly onto the wire.
2
) wires.