Table of contents 1 Safety instructions Important information ............................4 Warning notice..............................4 Intended use ............................... 4 Special safety precautions for installation ......................4 Qualified staff..............................5 Grounding ................................5 Mounting and installation ............................ 6 Transport ................................6 Disposal ................................6 Batteries and rechargeable batteries ......................
Page 3
8 To close the display Closing the display for indoor use ........................20 Closing the display for outdoor use ........................20 9 Technical data 10 SolarDisplayConfigurator Installation ................................ 22 System requirements ..........................22 Starting the installation ..........................22 Deinstallation ............................... 23 Configuration of the display ..........................
Safety instructions Important information Read these operating instructions before starting the unit. They provide you with important information on the use, safety and maintenance of the units. This helps you to protect yourself and prevent damage to the unit. During the lifetime of the unit keep the operating instructions in an accessible place at all times. Hand over the operating instructions to any future owner of the unit.
Fig.1 plastic lever included connectors 16,5 mm acrylic glass pane housing profile If the connectors once should solve themselves too easy, then spread them a little bit with a slot screwdriver. Fig. 2 connectors 25 mm acrylic glass pane housing profile Qualified staff The operating instructions are intended for trained professional electricians, familiar with the safety standards of electrical technology and industrial electronics.
Mounting and installation The attachment options for the units were conceived in such a way as to ensure safe, reliable mounting. The user must ensure that the used fixing material guarantees, under the given surrounding conditions, a secure mounting. When installing and commissioning please note the appropriate national and regional regulations. Transport The unit must be transported clean and dry in the original packing.
Copyright This documentation is protected by copyright. All rights are reserved. No part of this documentation may be translated without written permission by Siebert Industrieelektronik GmbH. No part of this documentation may be reproduced in any form by print, photocopy or other methods, or processed by using electronic systems, duplicated or disseminated.
Important start-up instructions During the commissioning of the display you need the following facilities for configuration: PC with the software Siebert 'SolarDisplayConfigurator' A suitable cable depending in the type of the display. With displays of type …-03 with USB interface the configuration is done via the integrated USB interface.
Displays for outdoor use, protection type IP54 Units for outdoor use have screwed plug-in connectors, sealed cable feed-throughs with rubber lips and climate compensation elements. The displays of the XC420 series are differed in the following interface versions: Order number. Interfaces...
Brightness control The brightness of the LEDs can be manually adjusted to the ambient brightness. Alternatively, the automatic brightness control can be activated with the 'SolarDisplayConfigurator'. The display automatically adjusts its luminosity to the ambient brightness. If the ambient brightness is lower, for example in cloudy sky or at night, the display dims down automatically to e.g.
Installation Requirements to the installation site The display is designed for wall mounting. The wall surface has to be plane and free of irregularities. The wall must have a sufficient capacity. Installation material The installation material shown below is included in delivery: Screws for wall mounting Dowels for wall mounting Spacers for wall mounting...
The connectors on devices for outdoor use are secured with torx screws all around against unintentional opening. For installation and disassembly a fitting torx wrench is included. To open the device remove the torx screws and keep them carefully for later assembly. Open the device by using the lever tool.
Use according proper mounting material if the screws and dowels included do not match. The spacers, in combination with the screws, allow a fastening of the device with a distance of approximately 10 mm to the wall. The cables can then be fed between wall and device (surface mounting). To fix the spacers during installation use the included hexagonal self-adhesive stripes.
Connection of the Ethernet cable Only valid for displays with Ethernet interface (XC4xx-xxx-x-05). Displays with Ethernet interface are connected with an Ethernet cable cat. 5 or higher. Modern PCs or laptops recognize the cable type automatically. If your display is operated with older network components, the following cables are required: ...
Data source connection The digital display is purely an information output device. It converts the sent data from the inverter/data logger/power meter into visual information but does not define the content of the numerical information. Power meter/inverter/data logger with S0 interface Each power meter, data logger or inverter with impulse interface according to IEC/EN 62053-31 or DIN 43864 is suitable for the use with the large size displays.
Inverter/data logger with RS485 interface The connection of the inverter/data logger is at the point marked RS485 terminal as shown below. As connecting cable type J-Y(St)-Y, 2 x 2 x 0,6 mm² or similar is used. The maximum length are 1.000 meters.
Connection of the Ethernet cable Only valid for displays with Ethernet interface (XC4xx-xxx-x-05). Displays with Ethernet interface are connected with an Ethernet cable cat. 5 or higher. Modern PCs or laptops recognize the cable type automatically. If your display is operated with older network components, the following cables are required: ...
Start-up and configuration Siebert Solar Displays can be configured and operated via various interfaces. In addition to a PC or laptop, depending on the interface of the display, you will also need further tools for configuration/operation. Displays with USB interface (XC4xx-xxx-x-03) The configuration and the changing of values is carried out via the USB interface.
Configuration of the display The configuration is only done with the Windows software 'Siebert SolarDisplayConfigurator'. The steps required for configuration are described in detail in the documentation of the 'SolarDisplayConfigurator' program. After you have successfully completed the configuration, the software is needed only if something changes in the solar system.
To close the display Closing the display for indoor use Insert the front pane and the connectors. Spread the connectors slightly with a screwdriver before inserting so that they are stuck firmly in the housing frame. Check that the connectors are fixed so tightly after insertion that they cannot be removed without tools (lever tools).
Technicshe Technical data The following figures show the housing dimensions and the holes for wall mounting. holes for wall mounting 5 Series XC420 Dimensions (W x H x D) 400 x 280 x 62 mm LED display digit height 25 mm Upper LED display 4 digits Middle LED display...
A user input from you is only required, if you do not want to install the software in the therefor provided directory file. In this case, please modify the target directory accordingly. After successful installation, the software can be called up via the Start Menu. Click Start > Siebert > SolarDisplayConfigurator x_xx_xxx.
Deinstallation To uninstall the Siebert 'SolarDisplayConfigurator' open 'Programmes and Features' via the Windows settings. Choose the Siebert 'SolarDisplayConfigurator' from the list and click Uninstall. BAL XC420 2.00 23/47...
A patch cable, if, for configuration, you connect the PC over a switch or router with the display. Control concept The configuration of the display is done in several steps, which you are guided through by the Siebert 'SolarDisplayConfigurator'. Here each step has an own dialog box. As the next step will not be called up before all previous entries are correct a faulty operation is almost impossible.
Configuration mode After starting the software you need to set the configuration mode. The complete configuration of the display resp. of the gateway is set in mode 'Configuration' or 'Gateway'. Thereby all required parameters are set. A gateway collects data from data loggers that do not have a network interface and makes that data available in the network for the display.
Daughter displays Each standard display is automatically configured to send the displayed data via the second RS485 interface. The daughter display can evaluate and display the data of the standard display via its first RS485 interface. The daughter display also sends the displayed data via the RS485 interface so that several daughter displays can be cascaded.
Page 27
If you have decided on the expert mode then select whether you want to parameterize an individual ®' display by clicking 'XC-Board or a gateway solution. Then click 'Next'. BAL XC420 2.00 27/47...
Interface Here you set via which interface the display is connected with the inverter. If the inverter, resp. the data logger is connected to the display via a S0 interface, resp. a pulse exit, please select 'S0 Pulse'. For displays which are connected to the converter, resp. the data logger via a serial interface select 'RS485'.
Selection of display or gateway In the next step all displays connected to the PC via the configuration interface (Ethernet, USB or Bluetooth) are automatically recognized. To select the display double-click the desired line in the display list. The selected display is marked by a green arrow.
Selection of the display or the gateway with Ethernet connection By clicking the button 'Search' button, the recognition of the display can be started new at any time. In the field 'IP address' you can enter the IP address of the display manually. Then click the 'Add' button, so that the display is added to the display list.
Network set-up If the display is connected to the PC via a network, the network parameters have to be set under which the display has to be contacted in the network. Choosing the option 'DHCP' (Dynamic Host Configuration Protocol) the display is integrated automatically to the existing network.
S0 parameter If the display or the gateway is connected to an inverter or a data logger via the S0 interface the following data of the solar system have to be set: Enter the peak performance of the solar system in the input field 'Maximum power' and select the corresponding unit value in the drop-down list.
Select inverter If the display or the gateway is connected to an inverter, resp. to a data logger via the serial interface or Ethernet, the type of inverter, resp. of the data logger and the used data protocol must be set. Choose the inverter, resp.
Set the inverter Data loggers with network interface have to be configured via their network parameters in the display so that it can make the connections for data transmission. In the field 'Address' you enter the IP-address of the data logger in the network. If the data logger supports multiple network protocols select the desired protocol in the dropdown list 'Network protocol'.
Server settings of the display For some Ethernet data loggers, the display must act as a server, and the data logger connects to the display as a client. 'Server Port' specifies the network port via which the client can connect to the display.
Define the display In this step the illustration of information of the display is defined. It is defined which line shows which value and how many digits each value has and in what units the values are displayed. In the column 'Measured variable' you choose what line of the display shows which measured variable.
General settings In the field 'CO2 factor', the conversion factor, which is needed to calculate the CO2 reduction out of the total energy, is determined. Note The CO2 reduction is a measure for the contribution of climate protection. The CO2 factor varies regionally and depends on the mix of electricity as well as the technology to generate electricity.
Power saving mode At this point, the energy saving mode can be switched on and off. When the energy saving mode is activated, the display is darkened for the defined period of time. This means that the LED display of the display is switched off and on at a specific time.
Brightness The static brightness of the display can be set with the entry field 'Brightness'. The display then shines constantly with the set value. If the display has a light sensor, you can activate this sensor via the 'Brightness control'. The brightness of the display varies, depending on the ambient brightness, between the values given in the entry fields 'Min.
If you are in 'Gateway' mode, you must select the interface of the inverter to be connected to the Siebert Ethernet Gateway. The data of the inverter can then be queried and displayed by a Siebert solar display with an Ethernet interface from the Siebert Ethernet Gateway.
Complete configuration In this step you transfer the previously made settings to the display. Click 'Next' to start the transfer of the configuration. After successful configuration of the display the shown dialog box appears. Then click 'OK', this ends the 'SolarDisplayConfigurator' and the display is successfully configured. If you have configured a virtual display the settings are saved in a configuration file and the memory location is shown in a display box.
Bluetooth-connection For displays of type ...-04 the configuration can additionally be done via Bluetooth. This exemplarily describes the Bluetooth installation and the connection with a Siebert display for a Bluetooth USB adapter. This requires that the Bluetooth USB adapter is used with the standard Windows drivers and no additional driver software is required.
Page 43
Under 'Add Device', select 'Bluetooth'. Windows will search and display Bluetooth devices. Select the Siebert-xxxx device. Several displays are distinguished by the last four digits of the Bluetooth ID (xxxx). BAL XC420 2.00 43/47...
Page 44
Testing the coupling Open the Windows settings (p.e.: Windows-button + i) and after select the point 'devices'. The connected display appears under 'Other devices'. For communication, the display uses the Bluetooth profile 'Serial Port Device'. For this purpose a virtual COM port is created. To get detailed information about Bluetooth communication, select 'Devices and Printers' under 'Related Settings'.
Page 45
Open the tab 'Services' of the properties dialogue box. The Bluetooth feature 'serial connection (SPP)' has to be activated for the display. The virtual COM port that is used for communication is specified thereafter. Open the 'Bluetooth tab' of the Properties dialog box. In the line 'Unique ID' you can identify the display.
Bug fixing Error description Solution The software can not be installed. Make sure that you have admin rights on your PC. Make sure that .NET Framework 4 is installed on your The display is not recognized over the network interface. The display is turned off.
Service and Support If you have any questions or want to take advantages of our services, please contact one of the following addresses: Germany Siebert Industrieelektronik GmbH Siebertstrasse, D-66571 Eppelborn Phone +49 (0)6806 980-0 Fax +49 (0)6806 980-999 info.de@siebert-solar.com France Siebert France Sarl 4 rue de l’Abbé...