After removal
An uninstalled axial piston unit must be preserved with corrosion protection for the
duration of storage.
The following instructions only refer to axial piston units operated with hydraulic
fluid on a mineral oil basis. Other hydraulic fluids require other specific
preservation measures. In such a case, consult your local contact person; you can
find their contact information at
www.boschrexroth.com/addresses
Bosch Rexroth recommends the following procedure:
1.
Clean the axial piston unit; see chapter 10.1 "Cleaning and care" on page 47.
2.
Drain the axial piston unit.
3.
For storage times up to 12 months: Moisten the inside of the axial piston unit
with mineral oil and fill with approx. 100 ml mineral oil.
For storage times up to 24 months: Fill the axial piston unit with VCI 329
corrosion protection (20 ml).
The filling is carried out via the drain port T
the axial piston unit", Fig. 14 to Fig. 16 on page 38.
4.
Plug all ports so they are airproof.
5.
Coat unpainted areas of the axial piston unit with mineral oil or suitable, easily
removable corrosion protection, e.g. acid-free grease.
6.
Package the axial piston unit with desiccant in corrosion protection film so it
is airproof.
7.
Store the axial piston unit in a shock-proof manner; see "Requirement"
on page 24 in this chapter.