GETTING TO KNOW THE MARK 2
The Mark2 is equipped with a new 24V high-performance compressor, and the outlet temperature can be lower than
the ambient temperature of 28℉ in 10 minutes. The new dual-hose exhaust system improves space cooling speed by
40% over the first generation. The classic handle design makes it easy to move. Using Mark2's special battery can
achieve a maximum continuous working time of about 5 hours.
1.Control Panel
8.Exhaust air inlet
2.Outlet air direction adjustment
9.Power input
3.Outlet air temperature display
10.Drain
4.Air filter
5.LED lights
6.Status light
7.Exhaust air outlet
* The batteries shown in this manual need to be purchased separately, please refer to the zerobreeze.com for more details.
** The cooling speed and maximum working time are measured under the experimental environment and are for reference only.
*** Mark2 already contains a set of intake and exhaust hoses. If you need a longer hose, learn more from zerobreeze.com.
03
1
2
5
6
3
8
4
9
10
Design and Compliance Notes
In order to ensure the optimal performance of our
products, the design specifications of the unit and
remote control are subject to change without prior
notice.
The Energy Rating for this unit is based on the
installation of two unextended exhaust ducts.
CONTROL PANEL&REMOTE CONTROL PANEL
Power Button
•When power on, press once to turn on, then press to turn off.
•After the unit is stopped, the compressor cannot be restarted for one minute. This is to protect the equipment.
LIGHT
ON/OFF
SPEED
FAN
SLEEP
COOL
STRONG
7
+Button
Increase blowing speed.
*Alternative function
Long press to increase temperature
display brightness.
FAN mode
Press the FAN button, the FAN indicator is
on, and the other modes are off.
When the air conditioner enters in FAN
mode, the compressor and exhaust fan
will be turned off after 5 seconds, and the
air conditioner status indicator will
change from blue to red.
When the FAN mode is switched to
another mode, the compressor will have a
protection delay of 1 minute before it
starts to work.
STRONG mode
Press the "STRONG" mode button, the
indicator lights up, and the other mode
lights go out.
The air conditioner enters the STRONG
mode and works at full load. The air
conditioner status indicator is blue.
SLEEP mode
Press the SLEEP mode button, the
indicator lights up, and the other mode
lights go out.
The air conditioner enters SLEEP mode
and works at low load. The air
-Button
conditioner status indicator is blue.
Decrease blowing speed
*Alternative function
Long press to decrease temperature
display brightness.
LIGHT button
Press the LIGHT button, the indicator
light is on, the front light is on, and
press it again, the light is off.
COOL mode
The default cooling mode, when the power
When the air conditioner is powered on,
supply voltage is lower than 19V, the air
there is no need to turn on the air
conditioner will stop working automatically.
conditioner, and the lighting can be
Press and hold the cooling mode control
turned on or off.
button(hold for 2 seconds), Mark 2 will
enter the car mode (tail indicator light will
Alternative function Long press for 3
be purple).In this mode, when the power
supply voltage is lower than 22V, the air
seconds, air outlet temperature display
conditioner will automatically power off to
switch between Fahrenheit and Celsius.
prevent the car battery from running out.
When the cooling mode button is pressed 
and hold for 2 seconds again, it switches to
the default cooling mode.
This setting has a memory function, that is,
after unplugging the power supply, when 
powered on next time it maintains the
Unplug the plastic sheet and use the
previous setting mode.
remote control.