VOLTAGE INDICATOR LDM - 10
DESCRIPTION
The LDM-10 device is used for
graphic presentation of the one-phase
voltage supply system level. Voltage
value is shown by means of a diode
line of 11 LED diodes. The range of
measure is from 195 to 245 V ~.
FEATURES
‫ ی‬Graphic presentation of the one-
phase voltage supply system le-
vel,
‫ ی‬voltage indication wide range from
195 to 245 V~,
‫ ی‬voltage value proportional to graph
height scale range 5 V,
‫ ی‬indication stability,
‫ ی‬indicated voltage value accuracy
±2,5 V,
‫ ی‬voltage critical values are signal-
led by diodes marked „≤195 V",
„≥245 V",
‫ ی‬TH-35 DIN rail installation.
The device is designed
for one-phase installation
and must be installed in
accordance with standar-
ds valid in a particular co-
CAUTION
untry. The device should
be connected according to the details
included in this operating manual. Instal-
lation, connection and control should be
carried out by a qualified electrician staff,
who act in accordance with the service
manual and the device functions. Disas-
sembling of the device is equal with a
loss of guarantee and can cause electric
shock. Before installation make sure the
connection cables are not under voltage.
The cruciform head screwdriver 3,5 mm
should be used to instal the device. Im-
proper transport, storage, and use of the
device influence its wrong functioning.
It is not advisable to instal the device in
the following cases: if any device part is
missing or the device is damaged or de-
formed. In case of improper functioning
of the device contact the producer.
Zakład Mechaniki i Elektroniki
ZAMEL sp.j.
J.W. Dzida, K. Łodzińska
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamel.pl, e-mail: marketing@zamel.pl
TECHNICAL PARAMETERS
Input (supply) terminals: L, N
Input rated voltage: 230 V~
Input voltage tolerance: from -15 to +10 %
Rated frequency: 50 / 60 Hz
Rated power consumption: 24 mA
Voltage indicator: 11 LED diodes
Voltage indicator accuracy: ±2,5 V
Number of terminal clamps: 2
Section of connecting cables: from 0,2 to 2,5 mm
Ambient temperature range: from -20 to +45
Operating position: free
Protection degree: IP20 (PN-EN 60529)
Overvoltage category: II
Pollution degree: 2
Dimensions (height / width / depth): monomodular (17,5 mm) 90x17,5x66 mm
Reference standards: PN-EN 60947-5-1, PN-EN 60947-1
APPEARANCE
Input (supply / measure)
terminals (L)
Voltage indicator
INSTRUCTION MANUAL
LDM - 10
Mounting: TH35 rail (PN-EN 60715)
Protection class: II
Impulse voltage: 1 kV (PN-EN 61000-4-5)
Weight: 56 g
PN-EN 61000-4-2,3,4,5,6,11
Input (supply) terminals (N)
2
C
o
ver. 0.4.2 _ 2006.06.20_11:00

Advertisement

loading

Summary of Contents for Zamel EXTA LDM-10

  • Page 1 VOLTAGE INDICATOR LDM - 10 INSTRUCTION MANUAL Zakład Mechaniki i Elektroniki ZAMEL sp.j. J.W. Dzida, K. Łodzińska ul. Zielona 27, 43-200 Pszczyna, Poland Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04 www.zamel.pl, e-mail: marketing@zamel.pl DESCRIPTION TECHNICAL PARAMETERS The LDM-10 device is used for LDM - 10 graphic presentation of the one-phase voltage supply system level. Voltage Input (supply) terminals: L, N value is shown by means of a diode Input rated voltage: 230 V~ line of 11 LED diodes. The range of...
  • Page 2 is con- stantly displayed. It lets the user to Device type: check its state all the time. 10 - one-phase 30 - three-phase Device symbol GUARANTEE CARD There is 24 months guarantee on the product 1. ZAMEL provides a two-year warranty for its products. 2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances, b) defects resulting from incorrect installation or operation of ZAMEL products, c) defects resulting from any changes made by CUSTOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold, d) defects resulting from force majeure or other aleatory events for which ZAMEL is not liable. 3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect. 4. ZAMEL will review complaints in accordance with existing regulations. 5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL.