Product Information

AXB-MPE+ Dual and Single Master Port Expanders

The AXB-MPE+ Dual and Single Master Port Expanders (FIG. 1) are AXCESS Control Systems
that are equipped with 12 AXlink ports that can control multiple audiovisual and lighting device up
to 3,000 feet from the control system. With the AXCESS programming software, you program the
AXC-EM cards, housed in the AXB-MPE+, to control the devices. The AXB-MPE+ Dual Master
Port Expander comes with two AXC-EM cards: the first card is the main processor and the second
is the stand-by processor. If a problem occurs with the first card, the AXB-MPE+ automatically
switches to the second card without disrupting service.
(front)
(front)
(rear)
EXPANSION IN/OUT ports
FIG. 1 AXB-MPE+ Master Port Expander and Dual Master Port Expander
The following table lists specifications for the AXB-MPE+:
AXB-MPE+ Specifications
Product Type
Program Control
Device Connectors
Expansion Connectors
Power
Dimensions (HWD)
Weight
Rack
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
AXlink status LED
PROGRAM port
PROGRAM RS-232 DIP switch
PROGRAM
AXLINK
RS-232
ON
PROGRAM MC1 port
PROGRAM RS-232 DIP switch
PROGRAM MC1
PROGRAM
MC1
RS-232
MC2
ON
IN
OUT
EXPANSION
AXlink 12
AXlink 11
AXlink 10
AXlink 9
AXlink bus expansion accessory
• AXC-EM Enhanced System Master Card built-in
• Two DB-9 RS-232 program ports
• DIP switch to set communication parameters
12 four-terminal connectors for captive wire compression
Two 4-pin modular telco connectors
• 11.8 to 16V DC, 250mA (using 2 AXC-EM cards)
(150 mA max draw per AXC-EM card)
• 2-pin captive-wire connector
Note: Power rating does not include externally connected AXlink devices.
1.72" x 19.00"(with rack ears) x 12.09" (4.37 cm x 48.26 cm x 30.71 cm)
6 lbs. (2.72 kg)
One standard rack unit high. Rack mounts included.
AXLINK PORT STATUS
1
2
3
4
5
6
7
8
9
10
AXLINK PORT STATUS
1
2
3
4
5
6
7
8
9
10
MC2 status LED
MC1 status LED
AXlink 8
AXlink 7
AXlink 6
AXlink 5
AXlink 4
AXlink connectors (1-12)
Product Information
AXLINK PORT STATUS LEDs
11
12
AXLINK PORT STATUS LEDs
11
12
PWR connector
12VDC
PROGRAM MC1 / MC2
AXlink 3
AXlink 2
AXlink 1
PWR
PROGRAM MC1 / MC2 port
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Axb-spe

Table of Contents