Page 1
AXB-MPE+ Master Port Expander AXB-SPE Slave Port Expander A x c e s s C e n t ra l C o n t r o l l e r s a n d C a r d s...
Page 2
This warranty extends only to products purchased directly from AMX Corporation or an Authorized AMX Dealer. AMX Corporation is not liable for any damages caused by its products or for the failure of its products to perform. This includes any lost profits, lost savings, incidental damages, or consequential damages. AMX Corporation is not liable for any claim made by a third party or by an AMX Dealer for a third party.
Installing the AXB-MPE+, AXB-SPE, and External Equipment ... 11 AXCESS Programming ... 11 Programming the AXB-MPE+ (One AXC-EM Card) ... 11 Programming the AXB-MPE+ Dual Master Port Expander (Two AXC-EM Cards) ... 12 AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander Table of Contents...
Page 4
Table of Contents AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander...
AXC-EM cards, housed in the AXB-MPE+, to control the devices. The AXB-MPE+ Dual Master Port Expander comes with two AXC-EM cards: the first card is the main processor and the second is the stand-by processor. If a problem occurs with the first card, the AXB-MPE+ automatically switches to the second card without disrupting service.
Page 6
PROGRAM port to download the AXCESS programs to the AXC-EM card. On the Dual Master Port Expander Plus, this port is designated as PROGRAM MC1 (Master Card #1). ity, and stop bits. The default settings are 1 stop bit, 8 data bits, no parity, and 38.4K baud.
AXB-SPE Slave Port Expander The AXB-SPE Slave Port Expander (FIG. 2) contains 12 AXlink ports that you can control with the AXB-MPE+. You can connect the AXB-SPE to the AXB-MPE+, and then control 12 additional AXlink bus lines. The AXB-SPE is an add-on device that connects to the AXB-MPE+ via RJ-11 modular connectors.
Page 8
Product Information AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander...
AXC-EM Master Cards, repeat this step on the second card. FIG. 2 AXC-EM DIP switch settings 4. Close the top panel, insert the Phillips-head screws, and tighten. AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander Lithium batteries and sockets Installation and Configuration...
To reset the DIP switch to its default settings, place all switches in the ON position. Parity 7 bits Unused 8 bits Unused Unused Unused Mark Even None AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander Baud Rates 1,200 2,400 4,800 9,600 19,200 38,400...
FIG. 3 MPE+ internal locations for AXC-EM cards and respective jumpers 4. To set the Port Expander to use one master, place the jumper from JP1A on pins 1 and 2 (SINGLE) and verify that the jumper from JP1B is also on pins 1 and 2. This setting allows the user to program the single AXC-EM card using either the front or rear Program ports.
You must connect a 12 VDC power supply to the AXB-MPE+ and AXB-SPE to control external equipment. If you connect external AMX equipment, refer to the associated AMX manuals for wiring and power supply information. This section describes how to wire a control system.
Before you replace the lithium batteries, verify that your AMX dealer has a current copy of control commands stored in your AXB-MPE+. This will avoid any inadvertent loss of data or a service outage.
5. Close the top panel, insert the Phillips-head screws, and tighten. 6. Return the AXB-EM+ to the equipment rack and reconnect all the connectors removed in step 2. Pin 1 Pin socket 3 AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander...
Install the AXB-MPE+ into a standard 19-inch rack using the supplied rack kit: 1. Mount the AXB-MPE+ and AXB-SPE in the equipment rack. Connect the power supply. 2. Mount the external AMX equipment where it will be used. AXCESS Programming You can program the AXC-EM Master Cards in the AXB-MPE+ with an AXCESS software program to control a wide variety of audiovisual, lighting, and audio equipment.
Programming the AXB-MPE+ Dual Master Port Expander (Two AXC-EM Cards) To program both AXC-EM Master Cards in the AXB-MPE+ Dual Master Port Expander: 1. Discharge the static electricity from your body by touching a grounded object.
Page 17
Installation and Configuration AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander...
Page 18
AMX reserves the right to alter specifications without notice at any time. brussels • dallas • los angeles • mexico city • philadelphia • shanghai • singapore • tampa • toronto* • york 3000 research drive, richardson, TX 75082 USA • 469.624.8000 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993...