Download Print this page

Motion Sensor Operation; Travel Mode - Larson Electronics SPLT-1.59K-800A-30-4X100W-LED-MS Installation Manual

Solar power generator with pneumatic light tower

Advertisement

MOTION SENSOR OPERATION

When the motion sensor detects movement, the LED lights are turned on.
Once the motion has stopped, the lights will turn off. Sensitivity, Time
Delay and Lux can be adjusted with their respective control dials on the
motion sensor.
1. The SENSITIVITY setting controls the distance in which the motion
sensor will work. The lowest setting will trigger the motion sensor
when motion is close. The highest setting will trigger the motion
sensor when motion is far.
2. The TIME setting controls how long the unit remains illuminated
following activation & after all motion ceases. The minimum time
(fully anti-clockwise) is approximately 5 seconds and the maximum
time (fully clockwise) is approximately 5 minutes. Set the control to
the desired setting between these limits.
3. The LUX setting determines the level of darkness required for the
unit to start operating. The setting is best achieved by the procedure
below:
Set the LUX control knob fully anti-clockwise. The unit will now start
operating at dusk. If you require the light to activate earlier, wait until the
ambient light level reaches the level of darkness at which you wish the lamp
to become operative, slowly rotate the control in a clockwise direction until a
point is reached where the lamp illuminates. Leave the control set at this
point. At this position, the unit should become operative at approximately the
same level of darkness each evening. Observe the operation of the unit. If
the unit is starting to operate too early (e.g. when it is quite light), adjust the
control slightly anti-clockwise. If the unit starts to operate too late (e.g.
dusk), adjust the control slightly clockwise. Continue to adjust until the unit
operates as desired.
MOTION SENSOR POSITION
The motion sensor's position can be adjusted by loosening the hand screw
on the side, repositioning, and tightening the hand screw.
GFCI
Trailer is equipped with a Ground Fault Circuit Interrupter. If tripped, check
ALL connections and reset. Check for foreign objects or water leaks.
Contact manufacturer for further troubleshooting.
SPLT-1.59K-800A-30-4X100W-LED-MS
Follow the steps below for lowering the mast and preparing the unit for
transportation or storage.
2.
To lower the mast, switch the pump OFF inside the
job box.
3.
Move the ball valve to the DOWN
position and allow the mast to fully
descend.
4.
Once the mast has been lowered make sure both light switches are
OFF, as well as:
A.
Turn the CHARGE CONTROLLER OFF
B.
Turn the SOLAR BREAKER OFF
C.
Turn the black & yellow DISCONNECT OFF
D.
Turn the POWER switch OFF
NOTE: If you aren't transporting, leave A,B,C ON for charging.
5.
Un-pin and remove the support legs for the solar panels. Secure them
in their mount with the latch.
6.
Unlatch the spring loaded pin and use 2
people to rotate the solar panel into

TRAVEL MODE.

11.
For the elevating panel array: Ensure
there is no slack in the winch cable.
Unlatch the spring loaded locking pins on
each side of the panel array and twist to
hold pin in the open position.
12.
Turn hand winch counter-clockwise to
lower solar panels fully. Check cables to
ensure they do not get caught while lowering.
Larson Electronics LLC
LOWERING MAST FOR TRANSPORT
ver.0118-1
IT IS NORMAL TO
HEAR A BEEP ONCE
TURNING THE
INVERTER OFF.
THIS WILL STOP
AFTER 5-10
SECONDS
4

Advertisement

loading