4. Swing the flow meter out of the cabinet and unhook the bracket from the cabinet.
5. Disconnect the flow meter from the unit by disconnecting the two hoses that are attached to the back of the flow meter.
6. Remove the bracket from the back of the flow meter.
7. Remove the cap from the top of the flow meter.
8. Turn the flow meter upside down to remove the ball.
9. Clean the inside of the flow meter with Isopropyl alcohol and dry thoroughly.
10. Clean the ball with a dry cloth.
NOTE: Do not use alcohol, cleanser or any detergent on the ball.
11. Assemble the flow meter in the reverser order.
12. Reinstall the flow meter into the machine in the reverse order.
NOTE: The blue hose is attached to the top of the flow meter. The red hose is attached to the bottom of the flow meter.
Draining the Smoke Hose:
1. Disconnect the unit from the power supply.
2. Disconnect the unit from external Air/Inert Gas source.
3. Disconnect the smoke hose from the back of the machine.
4. Hang the hose in a vertical position and place a container under the smoke hose.
5. Allow the excess oil to drain out of the smoke hose.
6. Reinstall the smoke hose.
TROUBLESHOOTING:
Problem
No Power Light
No Air Flow
Not Enough Smoke
Poor Smoke Density or Volume
WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov
4
Solution
Ensure that the power is properly Connected
• Open the flow control valve
• Check the air pump
• Check that the hoses are not kinked or pushed into machine
• Check the fluid level
• Open the flow control valve clockwise
• Check that the hoses are not kinked or pushed into machine
• Check the smoke light, if light is off press the smoke button. If
using the internal pump, ensure that the pump is turned on
• Turn the unit off. Wait 10 -20 minutes then start again.
• Insufficient smoke producing fluid: Refill
• Flow control valve is partially closed
• Smoke output hose is kinked
For parts or service contact the service department: 1-888-825-6989