822.381 BAMA / EN
Operating Instructions for LIS 101 Light Control System
Front of device
Fig. 1
Dimensional diagram of LIS 101 dimmer (dimensions in mm)
2.2
Electrical connection
ATTENTION!
Y
A fuse with a maximum rating of 10A must be inserted into the supply line to
prevent overloading.
ATTENTION!
Y
The "Switch" input of the dimmer can be activated with either "+12 V" or "Mi-
nus". A mixed connection of switches is not permitted for the connection of
multiple switches. Several switches being pressed at the same time would
lead to a short circuit.
For activation via "+12 V", the wire cross-section to the connector of the but-
ton must be selected sufficiently large in line with fuse F1.
LIS 101
Fig. 1
LIS 101 dimmer circuit diagram
ATTENTION!
Y
An incorrect connection (e.g. reverse poling) may result in irreparable da-
mage to the device.
1,5
Top
view
24
5 blade receptacles, 6.3mm
Date: 28.02.2011
2x ∅3
for attachment screw
12
45
5x soldered- -in blade terminals
straight 6.3 x 0.8
Light switch
Lighting
+
- -
*
* connect either to +12 V
or Minus
Fuse F1
max. 10A
- -
+