Operating Instructions for LIS 101 Light Control System
vehicle fuses
Environment
Minimum clearance
Fitting
2
1.3
System faults
The majority of faults are caused by blown fuses.
Flat
Please contact our customer service address if you cannot rectify the fault
using the following table.
ATTENTION!
Y
The LIS 101 dimmer can be damaged beyond repair by overloading. So:
Only replace defective fuses when the dimmer is not live and the
F
cause of the blown fuse is known.
Never bypass or repair defective fuses.
F
Fault
Lighting connected does
not work.
Connected lighting goes
out briefly and then goes
on again automatically.
Maintenance
1.4
The dimmer requires no maintenance.
2
Installation instructions
2.1
Mechanical installation
The device is designed for wall or floor installation.
Select a dry place for installation.
"
Ensure a minimum clearance to the surrounding fixtures and fittings:
"
Maintain a gap of at least 2cm on all sides (except mounted side).
F
Whilst in operation, the ambient temperature must not exceed +45 °C,
F
measured 1cm away from the sides of the device.
Use two screws (diameter 2.5mm) to screw the dimmer to a stable and
"
level surface (at the two attachment holes provided).
Possible cause
No 12V supply.
LIS 101 defective.
Wiring defective.
Short-circuit at output.
Internal temperature
monitor activated.
Date: 28.02.2011
Remedy
Check and switch on
supply voltage.
Check and replace fuse.
Replace LIS 101.
Check/replace connector
cable and 6.3mm
connector.
Rectify short-circuit.
Check lighting connected:
Maximum power of 120W
may not be exceeded.