Site Preparation

Installers may want to speak with customers in advance
and ask them to clean under the sink to save time. If a
basement installation is advisable, check area to
determine if extra fittings or hosing are required. Upon
arrival it is a good idea to check the condition of all
plumbing for potential leaks and advise customer so there
will be no misunderstandings in the event leaks occur.

Unit Preparation

Open shipping carton, remove components and check that
all parts are present.
Installation Steps
All plumbing must be completed in accordance with
provincial/state and local plumbing codes.
municipalities may require installation by a licensed
plumber. Check local authority prior to installation.
1. Faucet Installation
If the sink has a sprayer it may be disconnected for faucet
installation. (Installers should discuss this with customers).
A pipe cap or plug will be necessary to seal the sprayer
connection.
The faucet should be positioned so it empties into the sink
and the spout swivels freely for convenience. If sink has a
hole that can accommodate the RO faucet, no drilling Is
required. Proceed with mounting the faucet
Porcelain, Enamel, Ceramic on Metal or Cast Iron Sinks
For porcelain/enamel sinks marble or granite counter
tops refer to Manufacturer/Supplier for proper drilling
instructions.
Installation procedures for stainless steel sinks
Recommended tools:
 Center punch
 Variable speed drill
 High speed drill bits
 Protective gloves & eye protectors
Continued next section top of page.
Installation procedures for stainless steel sinks Con't
To make the faucet mounting hole (if sprayer or second
hole is not used), check below to make sure the drill does
not interfere with anything below the sink. Center punch a
small indent at the desired faucet location. (2`` flat surface
is required, not exceeding 1-1/4`` in thickness). Drill the
1/8" pilot hole. Drill the ½" hole for the faucet shank to fit
through. Clean up sharp edges.
Mounting the Faucet
Disassemble hardware from the threaded nipple, except
for chrome base plates and rubber washers.
Feed the threaded nipple through sink or counter
mounting hole and orient the faucet. From below sink or
counter, assemble the flat washer and hex nut on
threaded nipple and tighten by hand.
Some
faucet orientation, tighten with a wrench until secure.
2. Feed Water Adaptor Valve and Tubing Installation
The self piercing saddle tapping valve which is also
supplied is designed for use with 3/8`` to 1/2`` OD soft
copper supply tubing.
1. Turn off cold water valve from under sink or main
water line valve for whole house.
2. Before installing saddle tapping valve, make sure
piercing lance does not protrude beyond rubber
gasket.
3. Assemble saddle valve on copper tubing.
.
4. Tighten screw to fasten saddle valve to copper tubing.
5. Connect 1/4`` feed water tubing from the R/O inlet to
the quick connect fitting on feed water adaptor valve.
6. Turn handle clockwise to pierce soft copper tube until
valve is firmly seated. (Valve is closed in this position).
7. Turn on water supply to pressure cold water line and
check for leaks.
Figure 2. Feed Water Saddle Valve
After checking