Intellex 2.x Connection
COLOR
PIN
FUNCTION
Orange
1
Host A
Yellow
2
Host B
Orange
Auxiliary A
Auxiliary B
4
Yellow
3 2 1
TERMINATED
Terminate E1 on EIM #1
Intellex 2.x
(with DB9 Connector)
ADTT16E TOUCH TRACKER CONTROLLER WITH INTELLEX
INSTALLATION INSTRUCTIONS
COLOR
PIN
FUNCTION
Orange
1
SensorNet A
White
2
28 Vac
3
Red
Ground
Black
4
28 Vac
5
Yellow
SensorNet B
24 Vac A
Gr o und
24 Vac B
3
5
4
EIM #1
AS SY
0301- 0340-01 REV-
E1
RJ45
DB 9 (M )
PN 6003-0017-05 (RPNR00)
DB9 Connector
J-Box #1
P4
P1
P5
P2
P6
P3
P8
RJ45
Main
Touch Tracker
Serial Cable
4 of 6
J-Bo x #2
P4
P1
P5
P2
P6
P3
P8
5 4 3 2 1
UniCard
P3
COLOR
PIN
FUNCTION
Orange
1
SensorNet A
Yellow
2
SensorNet B
3
Black
24 Vac A
Red
4
Ground
White
5
24 Vac B
COLOR
PIN
FUNCTION
Orange P1 Lead 5 SensorNet A
Yellow
P1 Lead 6 SensorNet B
Black
P7 Lead 1
24 Vac A
Red
P7 Lead 2
Ground
P7 Lead 3
White
24 Vac B
The ma x imum combined
SensorNet cable length is
1000 m (3000').
Serial Cable Wiring
EIM Pin
COM1 PIN
2 (TX)
3 (RX)
5 (GND)
DB9 (F)
8000-2637-02, REV. C
5 4 3 2 1
UniCard
P3
2 (RX)
3 (TX)
5 (GND)