Summary of Contents for Flintec CC1W-30klb

  • Page 1 User’s Manual CC1W-30/50klb Page 1 of 21 DOC No. 0095771...
  • Page 2: Table Of Contents

    User Manual - CC1W Table of Contents Product description ................... 3 Mounting instructions ..................4 Base Unit .............................. 4 Antenna Recommendations ......................... 6 Remote Unit (Wireless Loadcell) ......................9 Battery Installation ..........................10 Equipment Maintenance ................. 11 Battery Replacement ...........................11 Operation ......................12 Base unit wireless channel selection (if needed) ..................13 Technical Specification ...................
  • Page 3: Product Description

    User Manual - CC1W 1. Product description The CC1W is a wireless version of our CC1 pump off control load cell. The CC1W utilizes the same proven design attributes as the CC1 - stainless steel, hermetic seal, fatigue rating and intrinsically safe operation.
  • Page 4: Mounting Instructions

    User Manual - CC1W 2. Mounting instructions IMPORTANT The employees responsible for the equipment installation and verification must take into consideration all the actions concerning this subject specified in IEC 60079-14:2013 ed. 5.0 (Electrical installations design, selection and erection) standard. In addition to general specifications associated with any system installed in hazardous locations, special attention should be paid for specific requirements regarding intrinsic safety (section 12).
  • Page 5 User Manual - CC1W When the magnet base is not directly attached due to non-metallic surface or space constraint, the base can be suitable fastened to any structure using brackets, plates or other type of support. DIN rail mount Pole mount with U- _________________________________________________________________ IMPORTANT In order to achieve the best performance a vertical alignment of the antenna...
  • Page 6: Antenna Recommendations

    User Manual - CC1W Antenna Recommendations Omni Directional Antenna  Antenna Height CC1W  base unit is equipped with an Omni- Taking advantage of the free directional antenna in order to provide positioning of the base antenna, the widest possible signal coverage. a convenient place in height with good clearance and away from ground must be considered.
  • Page 7 User Manual - CC1W When mounting inside an enclosure Page 7 of 21 DOC No. 0095771...
  • Page 8 User Manual - CC1W SIGNAL CABLE COLOR CODE Vref + GREEN Sig + WHITE Sig - BLACK Vref - YELLOW Shield GRAY Sig 2 + VIOLET Sig 2 - POWER CABLE COLOR CODE BLACK Ground YELLOW Shield 12 to 24VDC WARNING: Insulate unused leads to prevent shorting.
  • Page 9: Remote Unit (Wireless Loadcell)

    CC1W must be mounted as same as any other regular loadcell on the polished rod. _________________________________________________________________ IMPORTANT Position the remote unit (Plastic enclosure with Flintec Logo) direct to the base unit for better performance Page 9 of 21 DOC No. 0095771...
  • Page 10: Battery Installation

    User Manual - CC1W Battery Installation CC1W remote unit powered by a primary battery and must be fitted suitably in the battery compartment. The person in charge of the installation must verify that the battery not damaged or soaked. WARNING: This product is certified for use with TADIRAN TL-5930/F.
  • Page 11: Equipment Maintenance

    User Manual - CC1W 3. Equipment Maintenance Safety and health standards in the workplace must be strictly observed for all personnel conducting maintenance tasks. This manual must be read and kept carefully, in order to be always at the operator's disposal in case of need.
  • Page 12: Operation

    User Manual - CC1W 4. Operation 1. Disconnect or turn off power to the base unit. 2. Ensure the base antenna is connected. The remote’s antenna is installed by the manufacturer; to preserve safety certifications, it is not intended to be removed. 3.
  • Page 13: Base Unit Wireless Channel Selection (If Needed)

    User Manual - CC1W Base unit wireless channel selection (if needed) Remove up the base top cover. The 4 Philips head screws attached to the flat base cover loosened with the proper tool (manual Philips screwdriver). WARNING: Gently lift the cover to prevent damaged to the 3 LED light tubes attached to the cover.
  • Page 14: Technical Specification

    User Manual - CC1W 5. Technical Specification Standard Specifications 30k, 50k Rated Output mV/V 2.00 ± 0.5% mA (Optional) 4-20 Rated Position Output % FS (Stroke) ± 0.5 Nonlinearity % FS ± 0.25 Hysteresis % FS ± 0.25 Non-Repeatability % RO ±...
  • Page 15: Product Label

    User Manual - CC1W 6. Product Label Remote Unit (Transmitter) Equipment Group - All areas except Mines Label Equipment Category and Environment 1 G - Gas, Vapor, Mist Explosion Protection - Conformity with some of the IECs protection modes Protection Type - Intrinsic security “ia”...
  • Page 16: Product Dimensions

    User Manual - CC1W 7. Product Dimensions Remote Unit Page 16 of 21 DOC No. 0095771...
  • Page 17 User Manual - CC1W Base Unit (Receiver) Page 17 of 21 DOC No. 0095771...
  • Page 18: Safety Information

    User Manual - CC1W 8. Safety information Intended Usage A maximum temperature on the device enclosure must not reach temperatures higher than 80°C or lower than -55°C. This condition must be guaranteed permanently in order to be compliant with the intrinsic safety certification. The CC1W radio device must not be placed near heating or cooling sources that can put at risk.
  • Page 19 User Manual - CC1W FCC Certification Statement Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 20 User Manual - CC1W ISED RSS-Gen Notice “This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device.”...
  • Page 21 User Manual - CC1W FCC & ISED Canada RF Exposure Notice This device is intended to be mounted at a fixed location. This device is not intended to be operational while carried on a person. When used in an outdoor location: To comply with FCC/IC RF exposure limits for general population/uncontrolled exposure, the antenna(s) used for this transmitter must be installed on outdoor permanent structures to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in...