Solid fuel hot water boiler

Advertisement

HEATING SYSTEMS
EKY/B 20 - 60
SOLID FUEL HOT WATER BOILER
INSTALLATION AND USAGE MANUAL
(20 kW - 60kW)

Advertisement

loading
Need help?

Need help?

Do you have a question about the EKY/B 20 and is the answer not in the manual?

Questions and answers

Summary of Contents for Termodinamik EKY/B 20

  • Page 1 HEATING SYSTEMS EKY/B 20 - 60 SOLID FUEL HOT WATER BOILER INSTALLATION AND USAGE MANUAL (20 kW - 60kW)
  • Page 2 HEATING SYSTEMS FOREWORD Dear Customer; First of all, thank you for choosing our product. We hope you will get complete satisfaction from EKY/B Natural Draft Solid Fuel Boiler. We would like you to use your device with maximum efficiency, therefore please read this instruction book carefully before you start using the product and save it to refer to in the future.
  • Page 3: Table Of Contents

    HEATING SYSTEMS CONTENT Foreword EKY/B 20-60 Technical Specification..............1 Appliance Information..................3 Expansion Tank Selection..................5 EKY/B 20-60 Installation Chart................6 EKY/B 20-60 Expansion Tank Connection Chart............8 Chimney........................9 Operation of the Boiler..................11 Malfunctions and Troubleshooting..............16...
  • Page 4: Eky/B 20-60 Technical Specification

    HEATING SYSTEMS EKY/B 20-60 TECHNICAL SPECIFICATION EKY/B 20-60 SIDE VIEW...
  • Page 5 HEATING SYSTEMS EKY/B 20-60 TECHNICAL SPECIFICATION...
  • Page 6: Appliance Information

    HEATING SYSTEMS APPLIANCE INFORMATION EKY/B series boilers are designed to burn different types of fuels such as wood, walnut coal, quince coal and low-calorie brown coal in ranging capacities. As it is known, the shaft gasses which occur as a result of burning wood and coal, and condensation of water vapors shall take place.
  • Page 7 HEATING SYSTEMS In order to provide for the safety of the boiler and the assembly in case of power outages, the installation should have a by-pass line. Make sure to use a suitable check valve for all solid-fuel boilers and the pressure of the check valve should be equal to the maximum operating pressure of the boiler.
  • Page 8: Expansion Tank Selection

    HEATING SYSTEMS EXPANSION TANK SELECTION If Cast Sectional Boiler Capacity Boiler Capacity If Panel Radiators Heating Radiators (kW) (Kcal/h) are used are used 17.000 45 L 26 L 25.800 65 L 42 L 34.400 87 L 58 L 43.000 108 L 72 L 129.6 L 86.4 L...
  • Page 9: Eky/B 20-60 Installation Chart

    EKY-B 20-60 INSTALLATION CHART PUMP ON OUTLET A. Inlet to the Radiators B. Outlet from the Radiators C. Open Expansion Tank D. Inlet to the Expansion Tank E. Outlet from the Expansion Tank F. Messenger Line G. Radiators H. Air-Purge Valve I.
  • Page 10 EKY-B 20-60 INSTALLATION CHART PUMP ON INLET A. Inlet to the Radiators B. Outlet from the Radiators C. Open Expansion Tank D. Inlet to the Expansion Tank E. Outlet from the Expansion Tank F. Messenger Line G. Radiators H. Air-Purge Valve I.
  • Page 11: Eky/B 20-60 Expansion Tank Connection Chart

    HEATING SYSTEMS EKY/B 20-60 EXPANSION TANK CONNECTION CHART AIR VENT These are containers open to atmosphere and they should be MESSENGER installed a distance from the top of the PIPE INPUT TO pipe system for hot water systems or at...
  • Page 12: Chimney

    HEATING SYSTEMS CHIMNEY Connecting two solid fuel boilers to the same chimney is not recommended. Where this is not achievable and if calculations based to chimney cross section and height also allow using of other solid fuel boilers, then it is possible to connect multiple boilers into a common flue system.
  • Page 13 HEATING SYSTEMS If the shaft is made of iron sheet material, insulate the surrounding of the shaft and prevent the heat loss. The shaft should not have a sectional narrowness at any spot. Make sure not to install another appliance or more than one boiler to the same shaft. The boiler should not be installed to the shaft at a reverse angle preventing draught (see page 16).
  • Page 14: Operation Of The Boiler

    HEATING SYSTEMS OPERATION OF THE BOILER: 1. Fully open the shaft valve before operating the boiler. 2. Make sure that the system is full of water and the air in the system is removed before operation. The system should be slowly supplied with water to prevent air formation in the system. 3.
  • Page 15 20. Do not leave the boiler unattended for a long time, since it's required to change the settings of the thermostat regularly. You should contact Termodinamik Company for appliance fuel conversion. You should be informed by the Company on the conditions of conversion and the procedure to be followed.
  • Page 16 HEATING SYSTEMS DRAFT REGULATOR INSTALLATION Regulator installation: Screw the regulator with its 3/4" outer thread into the boiler socket with 3/4" inner thread. Seal the thread (e.g. with Siseal sealant, Teflon tape…). Turn the regulator so that for horizontal installation (a) the protrusion for bar placing pinpoints down wards, for vertical installation (b) it pinpoints to the front and for horizontal side installation (c) it pinpoints upwards.
  • Page 17 HEATING SYSTEMS BOILER WATER PROPERTIES In order to prevent calcification of water inside of the boiler and pipes, not so hard water should be used. (The water used in system must be over FS 25 which is international standarts for water hardness.) Boiler Feeding Boiler Filling Parameter...
  • Page 18 Make sure that dust and burning coals do not fall onto the electrical equipments of the boiler and the fan. Do not clean the boiler when it is operating. You are recommended to get your boiler maintained and controlled (paid) by the TERMODINAMIK AUTHORIZED SERVICE before the winter.
  • Page 19 HEATING SYSTEMS RADIATOR INSTALLATION CHART FOR MULTIPLE-STORE BUILDINGS OPEN EXPANSION TANK RADIATOR BOILER ROOM HEATER INSTALLATION CHART OPEN EXPANSION TANK BOILER RADIATOR...
  • Page 20: Malfunctions And Troubleshooting

    HEATING SYSTEMS MALFUNCTIONS AND TROUBLESHOOTING PROBLEM REASON SOLUTION - Inefficient draught - Calibrate the draft regulator Inefficient burning in the - Low-calorie or non-quality fuel - Clean the boiler. burning chamber. - Improper draft regulator settings - Use high-quality and dry fuel.
  • Page 21 PRODUCER INFORMATION PRODUCER TITLE ADRESS Kemalpaþa OSB Mah. 80. Sokak No:10 KEMALPAÞA-ÝZMÝR-TURKEY PHONE +90 (232) 877 12 12 +90 (232) 877 08 67 COMPANY EXECUTIVE SIGN - SEAL PRODUCT SOLID FUEL BOILER / NATURAL DRAFT TYPE OF PRODUCT MARK MODEL EKY/B BANDEROLE AND SERIAL NUMBER DATE AND PLACE OF DELIVERY...
  • Page 22 HEATING SYSTEMS Kemalpaþa OSB Mah. 80. Sokak No:10 KEMALPAÞA-ÝZMÝR-TURKEY Tel: +90 (232) 877 12 12 Fax: +90 (232) 877 08 67 www.termodinamik.com.tr...