Termodinamik DEK SERIES Installation And Usage Manual

Termodinamik DEK SERIES Installation And Usage Manual

Electrical boiler

Advertisement

H E A T I N G S Y S T E M S
DEK SERIES ELECTRICAL BOILER
INSTALLATION AND USAGE MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DEK SERIES and is the answer not in the manual?

Questions and answers

Summary of Contents for Termodinamik DEK SERIES

  • Page 1 H E A T I N G S Y S T E M S DEK SERIES ELECTRICAL BOILER INSTALLATION AND USAGE MANUAL...
  • Page 2 H E A T I N G S Y S T E M S...
  • Page 3 Termodinamik digital electric boiler provides economic, comfortable, unproblematic and environmentally solutions for heating and water heat systems. Termodinamik digital electrical boiler is heating equipment for apartments (flats) and small houses. It is economic to own and operate, runs trouble-free. The obvious advantages are;...
  • Page 4 H E A T I N G S Y S T E M S WARNING: FOR YOUR SAFETY Do not store or use gasoline or other Improper installation, adjustment, • flammable vapors and liquids in the alteration, service, or maintenance can vicinity of this or any other appliance.
  • Page 5: Table Of Contents

    10 WATER FILLING THE SYSTEM ............... 16 11 THE FIRST INSTALLATION OF THE BOILER ..........17 12 SAFETY ....................17 13 TERMODINAMIK DIGITAL ELECTRICAL BOILER TECHNICAL DATA…….18 14 DIGITAL BOARD USER’S GUIDE ............19 141. GENERAL VIEW OF THE BOARD ..........19 142.
  • Page 6: General

    Compliance with instructions in this user manual keeps your boiler efficient and running smoothly. Termodinamik Electrical Boiler has been delivered to you all checked and adjusted at the factory, ready to run. The service technician who will come for the start-up will perform fine adjustments and inform you.
  • Page 7: Introduction

    H E A T I N G S Y S T E M S 1. INTRODUCTION Your electrical boiler has been subjected to various safety tests during manufacturing processes. Your electrical boiler has been insulated all around with aluminum foiled fiberglass insulation and energy losses have been minimized.
  • Page 8: General Features

    ENVIRONMENTALLY FRIENDLY: The fuel is electric. Therefore, no flue gas, no chimney, no dirt of carbon-based fuels create. WIDE SPREAD SERVICE NETWORK: Termodinamik has wide spread established service network all over Turkey, ready to respond when you need. LONG LASTING: Your boiler is protected against effects of corrosion.
  • Page 9 H E A T I N G S Y S T E M S PACKING: External surface your boiler is painted sheet metal with protective film to prevent stretches during handling and assembly. Please peel off the film before start-up. Your boiler has been packed in a corrugated box for safe transport.
  • Page 10: Components (6-9-12 Kw)

    AUTOMATIC SAFETY VALVE RELAY BOX PUMP COVER AUTOMATIC AIR PURGER 3 WAY VALVE MOTOR MANUAL AIR PURGER WATER PRESSURE SWITCH TERMODINAMIK LABEL PUMP RING PRODUCT LABEL PUMP MOUNTING PLATE EXPANSION TANK (7 Liters) INNER TANK BODY COPPER PIPE (PUMP BOILER IN)
  • Page 11: Components (18-24-30-36 Kw)

    3 WAY VALVE MOTOR RELAY BOX WATER PRESSURE SWITCH AUTOMATIC AIR PURGER BOILER EXIT PIPE PUMP RING PUMP MOUNTING PLATE TERMODINAMIK LABEL EXPANSION TANK (7 - 10 Liters) EXTERNAL BODY (CASING) INNER TANK BODY PRODUCT LABEL COPPER PIPE (PUMP BOILERIN) HEATING RESISTANCE...
  • Page 12: Assembly & Startup

    H E A T I N G S Y S T E M S 5. ASSEMBLY & START-UP Your boiler must be hung on a wall firmly and rigidly. Water scale should be used for fine alignment. Minimum clearance and from the floor should be 50 cm, distance from the ceiling 40 cm.
  • Page 13: Mounting On The Wall

    H E A T I N G S Y S T E M S 6. MOUNTING ON THE WALL Explanations: 1 – Minimum distance to ceiling should be 400 mm to be able remove the resistance when necessary. 2 – Please make sure that the wall boiler is mounted rigid and strong.
  • Page 14: Connections Of The Boiler

    H E A T I N G S Y S T E M S 7. CONNECTIONS OF THE BOILER 1 Radiator return ¾‖ 2 Cold water entry ½‖ 3 Cold water exit ½‖ 4 To radiator ¾‖ Height : 723 mm Radiator in &...
  • Page 15: System Connection Details

    H E A T I N G S Y S T E M S 8. SYSTEM CONNECTION DETAILS Please use ball valve for the boiler – main water line connection in order to facilitate maintenance and service.
  • Page 16: Electrical Connections

    H E A T I N G S Y S T E M S 9 ELECTRICAL CONNECTIONS GROUND SAFETY THERMOSTAT Please make sure that boiler is grounded ROOM 3 WAY PUMP THERMOSTAT VALVE 6 - 9 kW (220 V) PUMP PUMP 3 WAY NEUTRAL...
  • Page 17 H E A T I N G S Y S T E M S Please make sure that boiler is grounded...
  • Page 18 H E A T I N G S Y S T E M S Please make sure that boiler is grounded (380 V)
  • Page 19: Water Filling The System

    H E A T I N G S Y S T E M S 10 WATER FILLING THE SYSTEM 1. Open the filling valve connected to radiator return valve to fill the system with water. Enclosed ―3/4 T’ ―mini-ball valve provided for water filling & discharge purposes. 2.
  • Page 20: The First Installation Of The Boiler

    H E A T I N G S Y S T E M S 11 THE FIRST INSTALLATION OF THE BOILER 1. Connect boiler phase and neutral power cables than check the connections. Do not open boiler until you are sure to be connections. Device contains mechanical high heat circuit breaker system therefore connections of the phase, neutral and ground connection is very important.
  • Page 21: Termodinamik Digital Electrical Boiler Technical Data

    Pressing the UP and ESC buttons with the same time for 3 seconds, Boiler locks the buttons until pressing the UP and ESC buttons with the same time for 3 seconds. 13 TERMODINAMIK DIGITAL ELECTRICAL BOILER TECHNICAL DATA DEK 12 DEK 24 MODELS >>...
  • Page 22: Digital Board User's Guide

    H E A T I N G S Y S T E M S 14 DIGITAL BOARD USER’S GUIDE 141 GENERAL VIEW OF THE BOARD 142 BUTTONS START BUTTON Turns the boiler ON STOP BUTTON Turns the boiler OFF ENTER BUTTON Value is used to access ESC BUTTON Cancel the entered value access...
  • Page 23 H E A T I N G S Y S T E M S UP / DOWN BUTTONS To change the values entered and circulation between the menu BUTTON CLOCK SET Using the adjust the time TIMER PROG RAM BUTTON Using to timer programming TIMER ON BUTT Using to set the boiler timer mode...
  • Page 24: 143 Display And Indicators

    H E A T I N G S Y S T E M S 143 DISPLAY AND INDICATORS Display of the boiler. Any kind of value entry and follow up can be made through this screen. INDICATORS HEAT LEVEL INDICATOR Shows boiler’s working heat steps SITUATION INDICATOR Shows active parts and working positions.
  • Page 25: 145. Turn On / Turn Of

    H E A T I N G S Y S T E M S Enter the value by up/down button than accept processing button. For returning the old value use button. 145 TURN ON / TURN OFF Set boiler winter or summer mode by button.
  • Page 26: 149 Timer Menu

    H E A T I N G S Y S T E M S 149 TIMER MENU 149.1 TIMER PROGRAMMING Push the button. At the display you see; TIMER MENU. You can chose TIMER PROGRAM by up/down buttons than accept election by button.
  • Page 27 H E A T I N G S Y S T E M S TIMER OFF time is activated. Repeat the same procedure as TIMER ON. After TIMER OFF time setting, TIMER SET value will be activated. That Value shows which time period of boiler heats TIMER ONOFF For new time period push button.
  • Page 28: 1410 Timer Operating

    H E A T I N G S Y S T E M S PROGRAM 1410 TIMER OPERATING Push button. If you have programmed any timer before, the light near the button will flash. Those programs shown at the display P1, P2, ... If use is at the programmed timer zone time part, P sign will flash.
  • Page 29: 1412 Errors / Notices

    H E A T I N G S Y S T E M S This is Language select parameter. It changes display language TURKISH or ENGLISH. If user enters 0: display language sets TURKISH, 1: enter display language sets ENGLISH. P2: Display light If this parameter chose ―Auto Back‖...
  • Page 30 H E A T I N G S Y S T E M S Low Pressure (Mechanic) If pressure of the boiler decreases under 0.6 bar you see that error. This error turns off boiler. 1412.2 NOTICES Low Pressure If pressure of the boiler decreases under 1 bar you see that notice. This notice does not turns off boiler.
  • Page 31 - Any failure in the device should only be handled by TERMODINAMIK AUTHORISED SERVICE PROVIDERS authorised by our Company. Otherwise the warranty will be void.
  • Page 32 H E A T I N G S Y S T E M S Kemalpaşa OSB Mah. 80. Sokak No:10 KEMALPAŞA-İZMİR-TURKEY Tel: +90 (232) 877 12 12 Fax: +90 (232) 877 08 67 www.termodinamik.com.tr...

This manual is also suitable for:

Dek 6Dek 12Dek 9Dek 24Dek 30Dek 36 ... Show all

Table of Contents

Save PDF