Supplier's model identifi er
Model
Certifi cate CE
Nominal capacity
Real capacity
Nominal pressure
Nominal heat rating
Useful rating
Heating time for DHW t 45°C
Heat loss at 60° Celsius
Hot water fl ow rate
supply at 30K
supply at 45K
Erp
Declared Load profi le
Water heating effi ciency ηwh
Water Heating effi ciency class
Daily electricity consumption Q
Daily fuel consumption Q
Sound power level LWA L
Emissions of nitrogen oxides
Annual electricity consumption AEC
Annual fuel consumption AFC
Mixed water at 40°C V40
Set-point temperature "out of the box"
Thermostat temperature settings
Gas supply pressure
G20 Methane
G30 Butane LPG
G31 Propane LPG
gas consumption
G20 Methane
G30 Butane LPG
G31 Propane LPG
Combustion gas values
Draught
Flue gas fl ow rate
Flue gas temperature
For the list of equivalent models refer to Annex A, an integral part of this booklet.
The products without the label and its board for sets of heaters and solar devices, provided for in Regulation 812/2013,
are not intended for use in such sets.
elec
fuel
WA
120
I
120
I
115
bar
8
kW
7,5
kW
6,4
min.
63
W
260
I/h
182
l/h
121
L
%
54,5
B
kWh
--
kWh
24,277
dB
55
[mg/kWh]
143
kWh/annum
--
GJ/annum
17
l
177
°C
60
5
mbar
20
mbar
28 ÷ 30
mbar
37
m3/h
0,794
Kg/h
0,591
Kg/h
0,583
mbar
0,015
g/sec
5,4
°C
172
SGA CA
150
200
51CL3938
150
200
155
195
8
8
8,4
10,1
7,2
8,6
73
73
300
330
205
245
136
163
L
XL
55,7
59,7
B
B
--
--
23,728
35,808
55
55
143
154
--
--
17
25
215
271
60
60
5
5
20
20
28 ÷ 30
28 ÷ 30
37
37
0,889
1,069
0,662
0,795
0,652
0,784
0,015
0,015
5,4
7,3
186
208
GB