GROUND LINER®ETL
MONOCOLOR CONNECTIONS
MONOCOLOR NO DIMMABLE
A
PSU 24V DC - 320W
Line
Maximum 5 luminaires of 1 meter each line connected with PSU 24V DC -
320W (15m.)
Maximum 5 meters from power supply to rst luminaire
M030360
This connection to be
made inside outer body
NOTE:
All wiring outside of outer
bodies
must be run thru conduit!
POWER + CONTROL
Remote power supply
to be connected to fixtures
inside a nema style (or equal)
enclosure (by others), using
appropriate wirenuts.
Lineardrive 720
Dimmer Basic
This connection to be
made inside outer body
M030360
M030360
CONTROLLER
Dimmer Basic
Maximum 5 luminaires of 1 meter (15 meters) per line connected to
lineardrive 720D (PSU 24V DC - 320W)
Maximum 5 meters from power supply to rst luminaire
Maximum 3 lines of 5 luminaires of 1 meter each line in parallel connection
to PSU 24V DC - 320W (15m.)
Each line must have one dimmer basic
Maximum 5 meters from power supply to rst luminaire
This connection to be
made inside outer body
B
DIMMABLE MONOCOLOR
Lineardrive
PSU 24V DC - 320W
PSU 24V DC - 320W
Line
Remote power supplies
to be connected to fixtures
inside a nema style (or equal)
enclosure (by others), using
appropriate wirenuts.